Physiology of the third heart sound: novel insights from tissue Doppler imaging
Sanjiv J Shah1, Gregory M Marcus, Ivor L Gerber
1Division of Cardiology, Department of Medicine, University of California, San Francisco, California, USA.
Background:
The third heart sound (S(3)) is thought to be caused by the abrupt deceleration of left ventricular (LV) inflow during early diastole, increased LV filling pressures, and decreased LV compliance. We sought to determine whether the ratio of early mitral inflow velocity to diastolic velocity of the mitral annulus (E/E') could confirm the proposed mechanism of the S(3).
Methods:
A total of 90 subjects underwent phonocardiography, echocardiography, tissue Doppler imaging, and left-sided heart catheterization.
Results:
Phonocardiography detected an S(3) in 21 patients (23%). Subjects with an S(3) had lower ejection fraction (P = .0006) and increased E deceleration rate (P < .0001), E/E' (P < .0001) and filling pressures (P < .0001). The phonocardiographic S(3) confidence score correlated with E/E' (r = 0.46; P < .0001) and E deceleration rate (r = 0.43, P = .0001). Of the echocardiographic variables, only E/E' was independently associated with the S(3) confidence score (P = .009), independently of invasively determined LV filling pressures (P = .001).
Conclusions:
The most important determinants of the pathologic S(3) are an increased deceleration rate of early mitral inflow, elevated LV filling pressures, and abnormal compliance of the myocardium as measured by tissue Doppler imaging.
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Heart Sounds
Auscultation is the process of listening to these internal body sounds using a stethoscope. The heart produces four types of sounds, but only two—S1 and S2—can usually be heard with a stethoscope.
S1, also known as the "lub" sound, is caused by the closure of atrioventricular (A-V) valves at the...
Aortic Regurgitation I: Introduction
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Cardiovascular System Abnormal Findings II: Auscultation
Abnormal Heart Sounds
Gallops:
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for diagnosing...

