A priori selection of the regularization parameters in emission tomography by Fourier synthesis
D Mariano-Goulart1, P Maréchal, S Gratton
1Department of Nuclear Medicine, Lapeyronie University Hospital, 371 Avenue du Doyen G. Giraud, 34295 Montpellier Cedex 5, France. d-mariano_goulart@chu-montpellier.fr
Abstract:
This paper describes how the stability of the inverse problem underlying emission tomography can be measured and controlled in clinical settings. We show how the Lanczos approximation provides a way to regularize a certain class of iterative reconstruction algorithms through a given level of noise or resolution in the slices and for a given acquisition protocol. Moreover, we show how the same Lanczos approximation can be used to decide when the iterative reconstruction algorithm actually converges for a given machine precision. These ideas are illustrated by means of reconstructions of simulated and actual emission datasets.