Electromagnetic analysis of the slotted-tube resonator with a circular cross section for MRI applications

Nadia Benabdallah1, Nasreddine Benahmed, Boumediene Benyoucef

  • 1University of Tlemcen, PO Box 119, 13000 Tlemcen, Algeria.

Related Concept Videos

Magnetic Resonance Imaging01:24

Magnetic Resonance Imaging

Magnetic resonance imaging (MRI) is a noninvasive medical imaging technique based on a phenomenon of nuclear physics discovered in the 1930s, in which matter exposed to magnetic fields and radio waves was found to emit radio signals. In 1970, a physician and researcher named Raymond Damadian noticed that malignant (cancerous) tissue gave off different signals than normal body tissue. He applied for a patent for the first MRI scanning device in clinical use by the early 1980s. The early MRI...
Magnetic Field Of A Current Loop01:16

Magnetic Field Of A Current Loop

Consider a circular loop with a radius a, that carries a current I. The magnetic field due to the current at an arbitrary point P along the axis of the loop can be calculated using the Biot-Savart law.
Imaging Studies for Cardiovascular System IV: CMRI01:21

Imaging Studies for Cardiovascular System IV: CMRI

Cardiovascular magnetic resonance imaging, or CMRI, is a non-invasive diagnostic test that employs a magnetic field and radiofrequency waves to create precise images of the heart and arteries. It provides comprehensive information about cardiac anatomy, function, perfusion, and tissue characterization without ionizing radiation.IndicationsCMRI diagnoses various heart conditions, including tissue damage from heart attacks, ischemic heart disease, myocarditis, aortic issues (tears, aneurysms,...
Steady, Laminar Flow in Circular Tubes01:23

Steady, Laminar Flow in Circular Tubes

Hagen-Poiseuille flow describes a viscous fluid's steady, incompressible flow through a cylindrical tube with a constant radius R. This flow profile is often applied to understand fluid transport in narrow channels, such as capillaries. It serves as a foundational example of laminar flow. In this model, cylindrical coordinates (r,θ,z) are used to describe the radial (r), angular (θ), and axial (z) dimensions within the tube. For Hagen-Poiseuille flow, the velocity profile is purely axial,...
Mesh Analysis for AC Circuits01:12

Mesh Analysis for AC Circuits

In the domain of radio communication, the significance of impedance matching must be considered. It is crucial to ensure the efficient transmission of signals between radio transmitters and receivers. Achieving this balance involves using impedance-matching circuits, with one fundamental configuration comprising a resistor, capacitor, and inductor.
The process of harmonizing these impedances begins with a clear understanding of the input and output signals. Once these signals are known, the...