Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Experiment Video

Updated: Jul 13, 2026

Additive Manufacturing-Enabled Low-Cost Particle Detector
06:05

Additive Manufacturing-Enabled Low-Cost Particle Detector

Published on: March 24, 2023

Methodology for identifying particle sources in indoor environments.

A Gudmundsson1, J Löndahl, M Bohgard

  • 1Division of Ergonomics and Aerosol Technology, Lund University, P.O. Box 118, Lund, SE-221 00, Sweden.

Journal of Environmental Monitoring : JEM
|August 3, 2007
PubMed
Summary

Identifying indoor airborne particle sources is crucial for health. This study developed a method to pinpoint sources, finding textile handling, likely from detergent residues, as a major contributor.

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Transcriptome analysis of avian livers reveals different molecular changes to three urban pollutants: Soot, artificial light at night and noise.

Environmental pollution (Barking, Essex : 1987)·2024
Same author

Detection of SARS-CoV-2 RNA on surfaces in a COVID-19 hospital ward indicates airborne viral spread.

The Journal of hospital infection·2022
Same author

EuGMS Task and Finish group on Fall-Risk-Increasing Drugs (FRIDs): Position on Knowledge Dissemination, Management, and Future Research.

European geriatric medicine·2021
Same author

EuGMS Task and Finish group on Fall-Risk-Increasing Drugs (FRIDs): Position on Knowledge Dissemination, Management, and Future Research.

Drugs & aging·2019
Same author

Deposition of inhaled nanoparticles is reduced in subjects with COPD and correlates with the extent of emphysema: proof of concept for a novel diagnostic technique.

Clinical physiology and functional imaging·2018
Same author

Temperature-controlled airflow ventilation in operating rooms compared with laminar airflow and turbulent mixed airflow.

The Journal of hospital infection·2017

Area of Science:

  • Environmental Science
  • Indoor Air Quality
  • Particle Physics

Background:

  • Increasing concerns regarding airborne particles in indoor environments necessitate rapid source identification for effective mitigation.
  • Particles larger than 0.5 micrometers pose potential health risks and require specific detection methods.

Purpose of the Study:

  • To design and implement a methodology for identifying sources of airborne particles larger than 0.5 micrometers in indoor settings.
  • To evaluate the effectiveness of the developed methodology in real-world residential environments.

Main Methods:

  • A multi-step approach combining visual inspection of surfaces and potential sources, technical measurements of airborne particles with activity logging, and controlled characterization in a test chamber.
  • Application of the methodology in three residential houses in southern Sweden to identify particle emission sources.

More Related Videos

Composition and Distribution Analysis of Bioaerosols Under Different Environmental Conditions
05:45

Composition and Distribution Analysis of Bioaerosols Under Different Environmental Conditions

Published on: January 7, 2019

A Practical Guide on Coupling a Scanning Mobility Sizer and Inductively Coupled Plasma Mass Spectrometer (SMPS-ICPMS)
11:18

A Practical Guide on Coupling a Scanning Mobility Sizer and Inductively Coupled Plasma Mass Spectrometer (SMPS-ICPMS)

Published on: July 11, 2017

Related Experiment Videos

Last Updated: Jul 13, 2026

Additive Manufacturing-Enabled Low-Cost Particle Detector
06:05

Additive Manufacturing-Enabled Low-Cost Particle Detector

Published on: March 24, 2023

Composition and Distribution Analysis of Bioaerosols Under Different Environmental Conditions
05:45

Composition and Distribution Analysis of Bioaerosols Under Different Environmental Conditions

Published on: January 7, 2019

A Practical Guide on Coupling a Scanning Mobility Sizer and Inductively Coupled Plasma Mass Spectrometer (SMPS-ICPMS)
11:18

A Practical Guide on Coupling a Scanning Mobility Sizer and Inductively Coupled Plasma Mass Spectrometer (SMPS-ICPMS)

Published on: July 11, 2017

Main Results:

  • The study successfully identified major particle emission sources in the investigated houses.
  • Textile handling activities were pinpointed as a significant source of particle emissions.
  • Detergent zeolite residues were identified as the likely cause of particle generation during textile handling.

Conclusions:

  • The developed methodology is effective for identifying indoor airborne particle sources.
  • Understanding concentration variations, real-time monitoring, activity correlation, and laboratory simulations are key to successful source identification.
  • Textile handling, potentially linked to detergent residues, represents a significant indoor particle source requiring attention.