Related Experiment Video
Updated: Jul 13, 2026

Use of High-Throughput Automated Microbioreactor System for Production of Model IgG1 in CHO Cells
Published on: September 28, 2018
Fault detection and diagnosis in an industrial fed-batch cell culture process
Jon C Gunther1, Jeremy S Conner, Dale E Seborg
1Department of Chemical Engineering, University of California, Santa Barbara, California 93106-5080, USA.
Abstract:
A flexible process monitoring method was applied to industrial pilot plant cell culture data for the purpose of fault detection and diagnosis. Data from 23 batches, 20 normal operating conditions (NOC) and three abnormal, were available. A principal component analysis (PCA) model was constructed from 19 NOC batches, and the remaining NOC batch was used for model validation. Subsequently, the model was used to successfully detect (both offline and online) abnormal process conditions and to diagnose the root causes. This research demonstrates that data from a relatively small number of batches (approximately 20) can still be used to monitor for a wide range of process faults.
More Related Videos
Related Concept Videos
Fed-Batch Culture
Bioreactor Controls-I
Bioreactor Design and Operational System
Upstream Processing
Automated Microbial Diagnostics
Batch vs Continuous Culture