Related Experiment Video
Updated: Jul 13, 2026

A Whole Body Dosimetry Protocol for Peptide-Receptor Radionuclide Therapy (PRRT): 2D Planar Image and Hybrid 2D+3D SPECT/CT Image Methods
Published on: April 24, 2020
A phantom for effective dose measurement: organ dose distribution assessment based on a numerical approach
C Furstoss1, S Ménard, I Clairand
1Institute for Radiological Protection and Nuclear Safety BP 17, 92262 Fontenay-aux-Roses, France.
Abstract:
ICRP 60 has defined the personal dose equivalent Hp(10) as an estimator of the effective dose E. Personal dosimeters, worn on the trunk, allow the measurement of the quantity Hp(10). However, the characteristics of the instrumentation and the definition of Hp(10) itself can generate differences between the two quantities, depending on the energies and on the directional distribution of the incident radiation. The objective of this study is to evaluate the possibility of the measurement of the effective dose E using an instrumented anthropomorphic phantom at workplaces. In the first step of this study, calculations of the effective dose for standard configurations are made using the Monte Carlo code MCNPX. This paper presents the model of the numerical anthropomorphic phantom and the results for whole body irradiations by broad unidirectional or plane-parallel photon beams. The results agree with those calculated by Zankl et al., so confirming the good suitability of the code and the phantom used. Then, the dose distributions inside some organs are presented and the locations of future detectors for the instrumented phantom are discussed.
More Related Videos
06:20Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
07:57Positron Emission Tomography-based Dose Painting Radiation Therapy in a Glioblastoma Rat Model using the Small Animal Radiation Research Platform
Published on: March 24, 2022
Related Concept Videos
Biological Effects of Radiation
Measurement of Bioavailability: Pharmacodynamic Methods
Dosage Regimens: Partial Pharmacokinetic Parameters
Model-Independent Approaches for Pharmacokinetic Data: Noncompartmental Analysis
One important characteristic of noncompartmental analyses is that drug exposure increases proportionally with increasing doses. This relationship...
Model Approaches for Pharmacokinetic Data: Distributed Parameter Models
The distributed parameter models are specifically designed to account for variations and differences in some drug classes. This model is particularly useful for assessing regional concentrations of anticancer or...
Dose Size and Dosing Frequency: Determination Methods