Mechanical disturbances in Fourier spectrometers
Bortolino Saggin1, Lorenzo Comolli, Vittorio Formisano
1Department of Mechanics, Politecnico di Milano, Campus of Lecco, Via Marco D'Oggiono 18/A, 23900 Lecco, Italy. bortolino.saggin@polimi.it
Abstract:
Fourier spectrometers are sensitive to many kinds of disturbance. This focus is mainly on those connected to mechanical vibrations, assessing the relationships between the mechanical inputs and the deriving effects on the spectra. Mechanical vibrations have two main effects on the spectra, the addition of signals due to direct sensitivity to vibrations of the detectors (e.g., through piezoelectric effect) and the changes of the interferogram due to the interferometer optical components motion. The Fourier transform spectrometer considered in this study is based on the constant optical path step sampling achieved by using the interferogram of a reference laser as a trigger so, ideally insensitive to mirrors speed changes, however, the analysis will show how the effects of delays in the sampling chain can compromise the benefits of this configuration. The effects of the vibration of the interferometer optical alignment are considered as well, showing the effect produced on the interferograms and eventually on the spectra. Despite their nonmechanical nature, detector nonlinearity and internal optical reflections are considered as well because their effects, similar to the mechanical ones, could be confused with the latter while in spectra diagnostic it is often important to be able to distinguish between the two. For all the analyzed effects the quantitative relationships between the mechanical disturbances' amplitudes and spectral observed effects are derived.
Related Concept Videos
IR Spectrometers
Raman Spectroscopy Instrumentation: Overview
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
NMR Spectrometers: Resolution and Error Correction
¹H NMR: Interpreting Distorted and Overlapping Signals
As Δν decreases and the signals move closer, the doublets appear increasingly distorted. The intensities of the inner lines increase at the cost of those of the outer lines as the signals are slanted or...
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used.
NMR Spectrometers: Overview