Related Experiment Video
Updated: Jul 13, 2026

Post Column Derivatization Using Reaction Flow High Performance Liquid Chromatography Columns
Published on: April 26, 2016
[Simultaneous determination of iodate, chlorite and bromate in bottled drinking water by ion chromatography with
Yiqi Zhou1, Zijian Wang, Yiping Xu
1State Key Laboratory of Environmental Aquatic Chemistry, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, China. yqzhou@rcees.ac.cn
Abstract:
Iodate, chlorite and bromate in bottled water are disinfectant by-products (DBPs) from ozonation. The established methods for simultaneous determination of iodate, chlorite and bromate are mostly based on pre- or post-column chemical reaction in which the target compound was converted to another easily detectable species. However, the procedure suffers from several time-consuming reaction steps that involve multiple chemicals, or where the reagents themselves are toxic. In the present study, a rapid, highly sensitive, precise and accurate method was established, and a post-column reaction with sodium nitrite and acid solution of potassium bromide was employed to enhance sensitivity and to reduce interferences. Under optimized conditions, the method limits for iodate, chlorite and bromate were 0.5, 0.4 microg/L and 0.1 microg/L, respectively. Percentage recoveries of iodate, chlorite and bromate varied from 70.8% to 98.0%, 92.4% to 100% and 93.2% to 104.1% respectively with different spiked water samples. The proposed method was demonstrated for detecting the concentrations of iodate, chlorite and bromate in bottled water produced from different water sources. Results showed that severe bromate contamination was present in bottled mineral water purchased from Beijing supermarket, which used spring water or ground water as the sources.
More Related Videos
09:09A Facile Synthetic Method to Obtain Bismuth Oxyiodide Microspheres Highly Functional for the Photocatalytic Processes of Water Depuration
Published on: March 29, 2019
10:14Synthesis and Purification of Iodoaziridines Involving Quantitative Selection of the Optimal Stationary Phase for Chromatography
Published on: May 16, 2014
Related Concept Videos
Precipitation Titration: Endpoint Detection Methods
In the Volhard method, a standard excess of AgNO3 is first added to the...
Ion-Exchange Chromatography
Redox Titration: Iodimetry and Iodometry
Precipitation of Ions
The equation that describes the equilibrium between solid calcium carbonate and its solvated ions is:
Precipitation Titration Curve: Analysis
High-Performance Liquid Chromatography: Types of Detectors