Related Experiment Video
Updated: Jul 13, 2026

On-chip Isotachophoresis for Separation of Ions and Purification of Nucleic Acids
Published on: March 2, 2012
Chiral separation of FITC-labeled amino acids with gel electrochromatography using a polydimethylsiloxane
Hu-Lie Zeng1, Haifang Li, Xu Wang
1State Key Laboratory of Environmental Chemistry and Ecotoxicology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing, P.R. China.
Abstract:
A chiral separation model of gel electrochromatography in a polydimethylsiloxane (PDMS) microfluidic device for amino acids (AAs) is presented. Six pairs of fluorescein isothiocyanate (FITC)-labeled dansyl amino acids (Dns-AAs) were separated in a 36-mm effectual separation channel in less than 120 sec, with resolutions all above 0.96. This highly efficient PDMS chiral microfluidic chip was prepared by inserting the mixture solution of monomers, crosslinkers, and radical initiation into the microchannel via syringe. Specifically, allyl-gamma-cyclodextrin (CD) as a chiral selector and crosslinker was bonded in gamma-CD-bonded polyacrylamide (PAA) gel, which was the separation media, and was immobilized in a PDMS microchannel through the stable linkage of 3-(trimethoxysilyl)-propyl methacrylate (Bind-Silane, Sigma, St. Louis, MO, U.S.A.). The preparation not only permitted the prompt chiral separation of AAs, but also extended application of the PDMS microfluidic device by restraining its hydrophobicity through the PAA gel monolithic column. Furthermore, the longevity of the PDMS microfluidic device was prolonged significantly. This can also be a powerful way to develop a rapid and efficient bioanalysis method and portable analytical apparatus.
Related Concept Videos
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Two-dimensional Gel Electrophoresis
The first dimension separation uses the isoelectric focusing or IEF technique performed on immobilized pH gradient (IPG) strips that separate proteins according to their isoelectric points.
Biological samples, such as cells...
Silica Gel Column Chromatography: Overview
Polar components tend to bind strongly to the silica gel, causing them to move slowly through the column. In contrast, nonpolar compounds...
Affinity Chromatography
Size-Exclusion Chromatography
Silica particles offer advantages such as rigidity,...