Related Experiment Video
Updated: Jul 13, 2026

Experimental Methods for Spin- and Angle-Resolved Photoemission Spectroscopy Combined with Polarization-Variable Laser
Published on: June 28, 2018
Inelastic scattering of OH(X2Pi) with Ar and He: a combined polarization spectroscopy and quantum scattering study
Sarantos Marinakis1, Grant Paterson, Jacek Kłos
1School of Engineering and Physical Sciences, Heriot-Watt University, Edinburgh, UK.
Abstract:
One-colour polarization spectroscopy (PS) on the OH A (2)Sigma(+)- X (2)Pi(0,0) band has been used to measure the removal of bulk rotational angular momentum alignment of ground-state OH(X (2)Pi) in collisions with He and Ar. Pseudo-first-order PS signal decays at different collider partial pressures were used to determine second-order decay rate constants for the X (2)Pi(3/2), J = 1.5-6.5, e states. The PS signal decay rate constant, k(PS), is sensitive to all processes that remove population and destroy polarization. The contribution to k(PS) from pure (elastic) alignment depolarization within the initial level, k(DEP), can be extracted by subtracting the independently measured or predicted sum of the rate constants for total rotational energy transfer (RET), k(RET), and for Lambda-doublet changing, k(Lambda), collisions from k(PS). Literature values of k(RET) and k(Lambda) are available from experiments with He and Ar, and from quantum scattering calculations for Ar only. We therefore also present the results of new, exact, fully quantum mechanical calculations of k(RET) and k(Lambda) on the most recent ab initio OH(X)-He potential energy surface of Lee et al. [J. Chem. Phys. 2000, 113, 5736]. The results for k(DEP) from this subtraction for He are found to be modest, around 0.4 x 10(-10) cm(3) s(-1), whereas for Ar k(DEP) is found to range between 0.6 +/- 0.2 x 10(-10) cm(3) s(-1) and 1.7 +/- 0.3 x 10(-10) cm(3) s(-1), comparable to total population removal rate constants. The differences between k(DEP) for the two colliders are most likely explained by the presence of a substantially deeper attractive well for Ar than for He. The measurement of k(DEP) may provide a useful new tool that is more sensitive to the form of the long-range part of the intermolecular potential than rotational state-changing collisions.
Related Concept Videos
π Electron Effects on Chemical Shift: Overview
π Electron Effects on Chemical Shift: Aromatic and Antiaromatic Compounds
¹H NMR: Complex Splitting
Splitting diagrams or splitting tree diagrams are routinely used to depict such complex couplings. While drawing splitting diagrams, the splitting with the larger coupling constant is usually applied first.
UV–Vis Spectroscopy: Molecular Electronic Transitions
Atomic Emission Spectroscopy: Lab
Electron Paramagnetic Resonance (EPR) Spectroscopy: Organic Radicals

