Three-dimensional elemental mapping of phosphorus by quantitative electron spectroscopic tomography (QuEST)

M A Aronova1, Y C Kim, R Harmon

  • 1Laboratory of Bioengineering and Physical Science, NIBIB, National Institutes of Health, Bethesda, MD 20892, USA.

Summary

Quantitative electron spectroscopic tomography (QuEST) offers 3-D elemental mapping at the nanoscale. This technique accurately quantifies phosphorus distribution in cellular structures like ribosomes and chromatin.

Related Concept Videos

Electron Microscope Tomography and Single-particle Reconstruction01:07

Electron Microscope Tomography and Single-particle Reconstruction

Transmission electron microscopy (TEM) can be used to determine the 3D structure of biological samples with the help of techniques such as electron microscope tomography and single-particle reconstruction. While single-particle reconstruction can examine macromolecules and macromolecular complexes in vitro conditions only, tomography permits the study of cell components or small cells in vivo.
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
The Phosphorus Cycle01:21

The Phosphorus Cycle

Unlike carbon, water, and nitrogen, phosphorus is not present in the atmosphere as a gas. Instead, most phosphorus in the ecosystem exists as compounds, such as phosphate ions (PO43-), found in soil, water, sediment and rocks. Phosphorus is often a limiting nutrient (i.e., in short supply). Consequently, phosphorus is added to most agricultural fertilizers, which can cause environmental problems related to runoff in aquatic ecosystems.
Mass Analyzers: Common Types01:19

Mass Analyzers: Common Types

The quadrupole mass analyzer consists of four cylindrical metal rods arranged in a diamond carrying a DC voltage and a radio-frequency AC voltage. The motion of ions through the quadrupole depends on the field strength, causing only ions of a certain m/z to resonate successfully and strike the detector at a given field strength. Though the transmission rate for these analyzers is high, the exact elemental composition of the sample is not determined because of low resolution; however, they are...
¹³C NMR: Distortionless Enhancement by Polarization Transfer (DEPT)01:20

¹³C NMR: Distortionless Enhancement by Polarization Transfer (DEPT)

When proton-coupled carbon-13 spectra are simplified by a broadband proton decoupling technique, structural information about the coupled protons is lost. Distortionless enhancement by polarization transfer (DEPT) is a technique that provides information on the number of hydrogens attached to each carbon in a molecule. While the DEPT experiment utilizes complex pulse sequences, the pulse delay and flip angle are specifically manipulated. The resulting signals have different phases depending on...