Related Experiment Video
Updated: Jul 13, 2026

A Convenient Method for Extraction and Analysis with High-Pressure Liquid Chromatography of Catecholamine Neurotransmitters and Their Metabolites
Published on: March 1, 2018
Retention prediction of adrenoreceptor agonists and antagonists on a diol column in hydrophilic interaction
Noel S Quiming1, Nerissa L Denola, Ikuo Ueta
1School of Materials Science, Toyohashi University of Technology, Toyohashi 441-8580, Japan.
Abstract:
Retention prediction models using multiple linear regression (MLR) and artificial neural networks (ANN) were developed for adrenoreceptor agonists and antagonists chromatographed on a diol column under hydrophilic interaction chromatographic (HILIC) mode at three pH conditions (3.0, 4.0 and 5.0). Using stepwise MLR, the retention behavior of the analytes was satisfactorily described by a five-predictor model; the predictors being the percentage of acetonitrile in the mobile phase (% ACN), the logarithm of partition coefficient (log D), the number of hydrogen bond donor (HBD), the number of hydrogen bond acceptor (HBA), and the total absolute atomic charge of the molecule (TAAC). Among the five descriptors, % ACN had the strongest effect on the retention as indicated by its relatively higher standardized coefficient compared to the other four predictors. The inclusion of the four predictors which are related to the properties of the compounds (log D, HBD, HBA and TAAC), suggested hydrophilic interaction, hydrogen bonding and ionic interaction as possible mechanisms of retention of the analytes on the studied system. The models derived from MLR also showed adequate fit as proven by the high correlation (R2 as high as 0.9667) between observed and predicted log k values for the training set and good predictive power on the test set (R2 greater than 0.97). ANN analyses of the data were also conducted using the five predictors derived from MLR as inputs and log k as output. The trained ANNs showed better predictive abilities as compared to MLR models as indicated by relative higher R2 and lower root mean square error of predictions (RMSEP) for both training and test sets. The derived models can be used as references for method development and optimization of chromatographic conditions for the separation of adrenoreceptor agonists and antagonists.
More Related Videos
11:44Cellular Membrane Affinity Chromatography Columns to Identify Specialized Plant Metabolites Interacting with Immobilized Tropomyosin Kinase Receptor B
Published on: January 19, 2022
10:17High-throughput and Comprehensive Drug Surveillance Using Multisegment Injection-Capillary Electrophoresis-Mass Spectrometry
Published on: April 23, 2019
Related Concept Videos
Adrenergic Antagonists: Chemistry and Classification of ɑ-Receptor Blockers
Nonselective α-blockers: Nonselective α-blockers contain haloalkylamine or imidazoline moieties. Phenoxybenzamine, with a haloalkylamine...
Adrenergic Agonists: Chemistry and Structure-Activity Relationship
Aromatic ring substitutions: Substituting the aromatic ring with –OH groups at positions 3 and 4 yields catecholamines (e.g., epinephrine), which have a high affinity for adrenoceptors. Hydrogen bonding between –OH groups and receptors enhances adrenergic activity.
Separation of the aromatic...
Analyte Adsorption and Distribution
Adrenergic Antagonists: Pharmacological Actions of ɑ-Receptor Blockers
α1-blockers: These drugs inhibit α1-adrenoceptors on smooth muscle cells, resulting in vasodilation. This vasodilation lowers blood pressure, making α1-blockers valuable in treating hypertension. Additionally, α1-blockers effectively address urinary obstruction...
Silica Gel Column Chromatography: Overview
Polar components tend to bind strongly to the silica gel, causing them to move slowly through the column. In contrast, nonpolar compounds...
Affinity Chromatography