On-orbit vicarious calibration of ocean color sensors using an ocean surface reflectance model
P Jeremy Werdell1, Sean W Bailey, Bryan A Franz
1NASA Goddard Space Flight Center, Greenbelt, MD 20771, USA. paul.j.werdell@nasa.gov
Abstract:
Recent advances in global biogeochemical research demonstrate a critical need for long-term ocean color satellite data records of consistent high quality. To achieve that quality, spaceborne instruments require on-orbit vicarious calibration, where the integrated instrument and atmospheric correction system is adjusted using in situ normalized water-leaving radiances, such as those collected by the marine optical buoy (MOBY). Unfortunately, well-characterized time-series of in situ data are scarce for many historical satellite missions, in particular, the NASA coastal zone color scanner (CZCS) and the ocean color and temperature scanner (OCTS). Ocean surface reflectance models (ORMs) accurately reproduce spectra observed in clear marine waters, using only chlorophyll a (C(a)) as input, a measurement for which long-term in situ time series exist. Before recalibrating CZCS and OCTS using modeled radiances, however, we evaluate the approach with the Sea-viewing Wide-Field-of-view Sensor (SeaWiFS). Using annual C(a) climatologies as input into an ORM, we derive SeaWiFS vicarious gains that differ from the operational MOBY gains by less than +/-0.9% spectrally. In the context of generating decadal C(a) climate data records, we quantify the downstream effects of using these modeled gains by generating satellite-to-in situ data product validation statistics for comparison with the operational SeaWiFS results. Finally, we apply these methods to the CZCS and OCTS ocean color time series.
Related Concept Videos
Influence of Earth's Curvature and Atmospheric Refraction on Leveling
Precipitation Gravimetry
In determining nickel by gravimetric analysis, a precipitant of ethanolic dimethylglyoxime is added to a hot nickel salt solution. This is quickly followed by the dropwise addition of dilute ammonia solution until precipitation occurs. A...
Glassware Calibration
Volumetric flasks: Volumetric flasks are designed to prepare aqueous solutions of precise volumes accurately with a calibration line on the neck. To calibrate a volumetric flask, it is important to fill it with distilled...
Calibration Curves: Linear Least Squares
For data that follow a straight line, the standard method for fitting is the linear...
Instrument Calibration
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...