Related Experiment Video
Updated: Jul 13, 2026

A Protocol to Set Up Needle-Free Connector with Positive Displacement on Central Venous Catheter in Intensive Care Unit
Published on: July 13, 2019
Sapphire platinum detachable coil experience in a tertiary-care facility
Abutaher M Yahia1, Vickie Gordon, John Whapham
1Department of Neurology and Neurosurgery, Wayne State University, Detroit, MI, USA. yahia25@hotmail.com
Background:
The Guglielmi Detachable Coil introduced by the Boston Scientific Corporation has been widely used for endovascular coiling of aneurysm. Recently, Sapphire platinum detachable coils (eV3, Irvine, CA) have been introduced for aneurysm coiling. Herein, we report our clinical experience with the Sapphire coil to evaluate the incidence of coil related complications and the rate of aneurysm occlusion.
Methods:
Consecutive patients who underwent embolization with Sapphire detachable coils were prospectively enrolled from January 2004 to September 2004 and the data were retrospectively analyzed. Patient demographics, including age, gender, presenting symptoms, Hunt and Hess grade, Fisher grade and locations of the vascular anomalies were collected. Additionally, complications associated with the coils and rates of aneurysm occlusion were observed and the data compiled.
Results:
29 patients underwent Sapphire coil embolization for intracranial aneurysms. Mean age was 50 +/- 18 (mean +/- SD) years with 81% being females. Aneurysm neck reconstruction was required in 7 cases, 6 with Neuroform stent (5 unruptured aneurysms) and 1 with balloon assistance (ruptured aneurysm). In 7 cases, Sapphire coils were used along with other coils. There were no events of thromboembolism or ruptures of aneurysms during coil embolization. However, multi-diameter coils demonstrated stretching in 4 stent-assisted cases without any adverse consequences. Complete occlusion of the aneurysm was achieved in 79.31% of the patients, neck remnant in 6.89, and partial coiling was achieved in 13.79%.
Conclusion:
The Sapphire coil could safely be used in the treatment of both ruptured and unruptured aneurysms. However, multi-diameter non-stretch resistant coils may be associated with coil stretching when used in conjunction with a stent. Further study is still required for definitive results.
Related Concept Videos
Tertiary Healthcare System
Oxygen Delivering System III: Tracheostomy and T-piece
Tracheostomy
A tracheostomy is a surgically created opening (stoma) in the anterior part of the trachea. It is used to establish a patient airway, bypass an upper airway obstruction, simplify the removal of secretions, permit long-term...
Restorative Care
Tracheostomy: Procedure and Tubes
Tracheostomy tubes can be made of semiflexible plastic (polyurethane or silicone), rigid plastic, or metal, and they come in...
Secondary Healthcare System
Endotracheal Intubation II: Nursing Management
1. Nursing Care of Patients Before Intubation
Before the endotracheal intubation procedure, nurses play an essential role in ensuring the process goes smoothly. The nurses must be familiar with intubation...