Related Experiment Video
Updated: Jul 13, 2026

Endoscopy Guided Photoablation of Endometrial Cysts using a 980 nm Laser with a Contact Fiber in Mares
Published on: July 16, 2020
An impedance-controlled system for endometrial ablation: five-year follow-up of 107 patients
1Tagesklinik Altonaer Strasse, Altonaer Strasse 59-61, Hamburg 20357, Germany. agallinat@gmail.com
Objective:
To assess the safety, efficacy and data durability of the NovaSure endometrial ablation system 5 years after the procedure in women with severe menorrhagia secondary to dysfunctional uterine bleeding (DUB).
Study Design:
A prospective, single-arm, pilot study of 107 women undergoing endometrial ablation using the NovaSure system (Canadian Task Force classification II-1) at a specialized center for gynecologic endoscopy. The premenopausal women, with menorrhagia secondary to DUB unresponsive to medical therapy, had completed childbearing. A Pictorial Blood-Loss Assessment Chart was used to conduct a posttreatment evaluation of menstrual blood loss and bleeding pattern. Ablation was performed without any type of endometrial pretreatment.
Results:
No intraoperative or postoperative complications were observed. Treatment time averaged 94 seconds. At the 5-year follow-up, amenorrhea was reported by 75% of patients and successful reduction of bleeding was achieved in 98%, with hysterectomy and retreatment rates of 2.9% and 3.8%, respectively.
Conclusion:
Long-term clinical results indicate that the NovaSure system is a safe and effective method for treatment of women with menorrhagia secondary to DUB. NovaSure yields high amenorrhea and success rates and low surgical reintervention rates 5 years after treatment.