Long-term intraocular pressure fluctuation and progressive visual field deterioration in patients with glaucoma and low intraocular pressures after a triple procedure
Related Experiment Video
Updated: Jul 13, 2026

Translaminar Autonomous System Model for the Modulation of Intraocular and Intracranial Pressure in Human Donor Posterior Segments
Published on: April 24, 2020
Samin Hong1, Gong Je Seong, Young Jae Hong
1Institute of Vision Research, Department of Ophthalmology, Severance Hospital, Yonsei University College of Medicine, 134 Shinchon-dong, Seodaemun-gu, Seoul, 120-752 Korea.
Objective:
To evaluate the association of long-term intraocular pressure (IOP) fluctuation and visual field (VF) progression in patients with glaucoma and low IOP.
Methods:
Four hundred eight eyes with IOPs below 18 mm Hg after a triple procedure (phacoemulsification, posterior chamber intraocular lens implantation, and trabeculectomy) were included in this study. Measurements of IOP and VF were taken for at least 3 years after surgery. Based on the SD in postoperative IOPs, the sample was split into 2 groups (group 1: SD
Main Outcome Measures:
Intraocular pressure and VF progression.
Results:
The groups showed no differences in IOPs through the follow-up period and in the VF defect score 3 months after surgery. After 13 years, more patients with progressive VF deterioration were detected in group 2 than in group 1.
Conclusion:
Our results showed that larger long-term IOP fluctuation was associated with a progressive increase in the VF deterioration even though patients with glaucoma maintained their IOPs after the triple procedure.
Application To Clinical Practice:
The SD of long-term IOP should be less than 2 in patients with glaucoma, even if their IOPs drop below 18 mm Hg.
Trial Registration:
clinicaltrials.gov Identifier: NCT00428740.