Related Experiment Video
Updated: Jul 13, 2026

Measurement of Tissue Oxygenation Using Near-Infrared Spectroscopy in Patients Undergoing Hemodialysis
Published on: October 2, 2020
Pre- and postdialysis blood pressures are imprecise estimates of interdialytic ambulatory blood pressure
Rajiv Agarwal1, Aldo J Peixoto, Sergio F F Santos
1Division of Nephrology, Department of Medicine, Indiana University School of Medicine, and Richard L. Roudebush Veterans Affairs Medical Center, Indianapolis, Indiana 46202, USA. ragarwal@iupui.edu
Abstract:
BP readings that are obtained in the dialysis unit are commonly used to make therapeutic decisions by clinicians and to predict morbidity and mortality by epidemiologists. Dialysis unit BP are also incorporated in the recent guidelines to target BP control. The magnitude of the difference, overestimation or underestimation, and agreement between dialysis unit BP and ambulatory BP (ABP) are unknown. Articles were selected from Medline to identify those that reported both ABP and dialysis unit BP in hemodialysis patients. Bias was calculated as the difference between dialysis unit and the corresponding ABP. Agreement limits between the BP measurement techniques were assessed by pooled SD of the difference using Bland-Altman methods. Predialysis systolic BP generally overestimated ABP by a variable amount. The heterogeneity between BP measurements did not allow for pooling of the estimates. The agreement limits between the two BP was 41.7 to -25.2 mmHg. Predialysis diastolic BP also generally overestimated the ABP with wide agreement limits (23.7 to -18.9 mmHg). In contrast, postdialysis BP underestimated average ABP with wide agreement limits for both postdialysis systolic BP (33.1 to -36.3 mmHg) and diastolic BP (19.3 to -23.9 mmHg). Dialysis unit BP measurements are imprecise estimates of ABP. Better methods are needed for the assessment of BP in hemodialysis patients for clinical decision making.
Related Concept Videos
Pre-Procedural Guidelines for Assessing Blood Pressure
Errors occurring during blood pressure monitoring
Several factors...
Assessment of blood pressure in brachial artery(two-step method)
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Hemodialysis III: Nursing Management
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment: