Related Experiment Video
Updated: Jul 13, 2026

Dithranol as a Matrix for Matrix Assisted Laser Desorption/Ionization Imaging on a Fourier Transform Ion Cyclotron Resonance Mass Spectrometer
Published on: November 26, 2013
Methanol-associated matrix effects in electrospray ionization tandem mass spectrometry
1Department of Pathology, University of Michigan Health Sciences Center, Ann Arbor, MI, USA. annesley@umich.edu
Background:
Matrix effects can profoundly reduce the performance of electrospray ionization mass spectrometry. Preliminary observations indicated that the methanol used in the mobile phase could be a source of differential ionization or ion suppression.
Methods:
Drug stability studies, analysis of biological extracts, mixing experiments, and postcolumn infusions were used to test 9 commercial methanols for ionization differences in liquid chromatography-tandem mass spectrometry assays for immunosuppressants. Area responses for the drugs and internal standards were compared for mobile phases prepared with each selected methanol. Postcolumn infusion experiments were performed to confirm the degree of ionization differences occurring at the ion source, and to evaluate the proportions of ammonium, sodium, and potassium adducts.
Results:
The decrease in signal for the immunosuppressant drugs was shown to result from differential ionization associated with the selected methanols. Product ion intensity varied by 10-fold among the methanols tested. For sirolimus, tacrolimus, and mycophenolic acid, the percentage change in ionization was the same for the drug and its corresponding internal standard. Postcolumn sirolimus infusion evaluation revealed that a 1000-fold analyte concentration difference did not affect ionization. The proportions of ammonium, sodium, and potassium adducts of sirolimus precursor ions differed in relation to the source of methanol.
Conclusions:
Organic solvents used in mobile phases and extract preparation of biological samples may be associated with ion suppression, affecting adduct formation and assay sensitivity.
More Related Videos
06:56Characterization of Synthetic Polymers via Matrix Assisted Laser Desorption Ionization Time of Flight (MALDI-TOF) Mass Spectrometry
Published on: June 10, 2018
07:12An Efficient Sample Preparation Method to Enhance Carbohydrate Ion Signals in Matrix-assisted Laser Desorption/Ionization Mass Spectrometry
Published on: July 29, 2018
Related Concept Videos
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
Tandem Mass Spectrometry
Chemical Ionization (CI) Mass Spectrometry
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
MALDI-TOF Mass Spectrometry
Matrix-Assisted Laser Desorption Ionization (MALDI)