Related Experiment Video
Updated: Jul 13, 2026

Modified Posterior Vertebral Column Resection for Patients with Thoracolumbar Kyphotic Deformity
Published on: September 16, 2022
Cement leakage into the posterior spinal canal during balloon kyphoplasty: a case report
S Becker1, J Meissner, A Tuschel
1Spine Center, Orthopaedic Hospital Speising, Vienna, Austria. stephan.becker@oss.at
Abstract:
We report a case of cement leakage into the posterior spinal canal due to inadvertent pedicle perforation during balloon kyphoplasty. The leakage was corrected immediately without any sequelae. Features seen on radiography and the minimally invasive procedure used for removal are described. The postoperative radiographs of 100 consecutive patients treated with balloon kyphoplasty were subsequently reviewed. Only one patient had a similar leakage but had no neurological complications.