Related Experiment Video
Updated: Jul 12, 2026

Ion-Exchange Membranes for the Fabrication of Reverse Electrodialysis Device
Published on: July 20, 2021
Study of using microfiltration and reverse osmosis membrane technologies for reclaiming cooling water in the power
1Department of Civil and Environmental Engineering, Beijing Jiaotong University, China. jinli8212@hotmail.com
Abstract:
A study of using dual membrane technologies, microfiltration (MF) and reverse osmosis (RO), for reclaiming blowdown of the cooling tower was conducted at ZJK power plant, Hebei province, China. The study shows that the combined MF-RO system can effectively reduce water consumption in the power industry. The results indicate that MF process is capable of producing a filtrate suitable for RO treatment and achieving a silt density index (SDI) less than 2, turbidity of 0.2 NTU. The water quality of RO effluent is very good with an average conductivity of about 40 micros/cm and rejection of 98%. The product water is suitable for injection into the cooling tower to counteract with cooling water intrusion. After adopting this system, water-saving effectiveness as expressed in terms of cycles of concentration could be increased from 2.5-2.8 times to 5 times.
More Related Videos
09:39Proof-of-Concept for Gas-Entrapping Membranes Derived from Water-Loving SiO2/Si/SiO2 Wafers for Green Desalination
Published on: March 1, 2020
10:19Three-Dimensionally Printed Microfluidic Cross-flow System for Ultrafiltration/Nanofiltration Membrane Performance Testing
Published on: February 13, 2016
Related Concept Videos
Biological Treatment of Effluent and Waste Water
Osmosis and Osmotic Pressure of Solutions
Microbial Wastewater Treatment
Downstream Processing
Microbial Fuel Cells
Multiple Pipe Systems
Series Configuration