Related Experiment Video
Updated: Jul 12, 2026

Extraction of Organochlorine Pesticides from Plastic Pellets and Plastic Type Analysis
Published on: July 1, 2017
[Study on the method for determination of pentachlorophenol in water]
Ying Zhou1, Xianfang Wu, Weidong Qu
1Key Laboratory of Public Health Safety, Ministry of Education School of Public Health, Fudan University, Shanghai 200032, China.
Objective:
To establish a method for sensitive and rapid determination of pentachlorophenol (PCP) in different water.
Methods:
Based on the actual national standard detection method of PCP, gas chromatographic conditions and quantitative method were modified and optimized. The modified method was used for the determination of pentachlorophenol in samples from natural water, output water and tap water.
Results:
A modified method for the detection of PCP in drinking water samples was developed with the conditions of gas chromatography as follows: the capillary column was used for separation and tribromophenol (TBP) as internal standard for quantification, the linear range were 0.1 - 10 microg/L, and the correlation coefficient was 0.9999. The limit of detection was 4.5 ng/L. Recoveries were between 90.1% and 98.4%, and RSD was less than 4.1% .
Conclusion:
The proposed method is a sensitive and accurate method for trace analysis of PCP in different water.