Pulse pressure variation as a tool to detect hypovolaemia during pneumoperitoneum
F Bliacheriene1, S B Machado, E B Fonseca
1Clinical Investigation Laboratory L. I. M. 8 School of Medicine-University of Sao Paulo, Sao Paulo, Brazil. fernandobli@uol.com.br
Background:
Pulse pressure variation (DeltaPP) and systolic pressure variation (SPV) induced by mechanical ventilation have been proposed to detect hypovolaemia and guide fluid therapy. During laparoscopic surgery, chest compliance is decreased by pneumoperitoneum. This may affect the value of SPV and DeltaPP as indicators of intravascular volume status. Thereby, we investigated the effects of pneumoperitoneum and hypovolaemia on SPV and DeltaPP.
Methods:
We measured DeltaPP, SPV and the inspiratory (Deltaup) and expiratory (Deltadown) components of SPV, at baseline, during pneumoperitoneum, during pneumoperitoneum and hypovolaemia and after the return to baseline conditions, in 11 mechanically ventilated rabbits. Pneumoperitoneum was induced by inflating the abdomen with carbon dioxide, and hypovolaemia was induced by controlled haemorrhage.
Results:
Pneumoperitoneum induced an increase in SPV from 8.5 +/- 1.6 to 13.3 +/- 2.6 mmHg (+56%, P < 0.05) as a result of an increase in Deltaup from 2.0 +/- 1.0 to 6.7 +/- 2.1 mmHg (+236%, P < 0.05), but no significant change in Deltadown, nor in DeltaPP. Haemorrhage induced a significant (P < 0.05) increase in SPV from 13.3 +/- 2.6 to 19.9 +/- 3.7 mmHg (+50%), in Deltadown from 6.6 +/- 3.3 to 14.0 +/- 4.9 mmHg (+112%) and in DeltaPP from 11.1 +/- 4.8 to 24.9 +/- 9.8% (+124%) but no change in Deltaup. All parameters returned to baseline values after blood re-infusion and abdominal deflation.
Conclusions:
SPV is modified by haemorrhage but it is also influenced by pneumoperitoneum. In contrast, DeltaPP is modified by haemorrhage but not by pneumoperitoneum. These findings suggest that DeltaPP should be used preferentially instead of SPV to detect hypovolaemia and guide fluid therapy during laparoscopic surgery.
Related Concept Videos
Measurement of Blood Pressure
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Pneumothorax II: Pathophysiology
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...