O-cresol Concentration Online Measurement Based On Near Infrared Spectroscopy Via Partial Least Square Regression
Published on: November 8, 2019
Improving the robustness of a partial least squares (PLS) model based on pure component selectivity analysis and
Youngbok Lee1, Hoeil Chung, Mark A Arnold
1Department of Chemistry, College of Natural Sciences, Hanyang University Haengdang-Dong, Seoul 133-791, Republic of Korea.
Abstract:
Pure component selectivity analysis (PCSA) was successfully utilized to enhance the robustness of a partial least squares (PLS) model by examining the selectivity of a given component to other components. The samples used in this study were composed of NH4OH, H2O2 and H2O, a popular etchant solution in the electronic industry. Corresponding near-infrared (NIR) spectra (9000-7500 cm(-1)) were used to build PLS models. The selective determination of H2O2 without influences from NH4OH and H2O was a key issue since its molecular structure is similar to that of H2O and NH4OH also has a hydroxyl functional group. The best spectral ranges for the determination of NH4OH and H2O2 were found with the use of moving window PLS (MW-PLS) and corresponding selectivity was examined by pure component selectivity analysis. The PLS calibration for NH4OH was free from interferences from the other components due to the presence of its unique NH absorption bands. Since the spectral variation from H2O2 was broadly overlapping and much less distinct than that from NH(4)OH, the selectivity and prediction performance for the H2O2 calibration were sensitively varied depending on the spectral ranges and number of factors used. PCSA, based on the comparison between regression vectors from PLS and the net analyte signal (NAS), was an effective method to prevent over-fitting of the H2O2 calibration. A robust H2O2 calibration model with minimal interferences from other components was developed. PCSA should be included as a standard method in PLS calibrations where prediction error only is the usual measure of performance.
Related Concept Videos
Methods of Medium Optimization
Regioselectivity of Electrophilic Additions-Peroxide Effect
Mechanistic Models: Compartment Models in Individual and Population Analysis
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
Parameters Affecting Nonlinear Elimination: Zero-Order Input, First-Order Absorption and Two-Compartment Model
When a drug is administered through a constant intravenous infusion and eliminated via nonlinear pharmacokinetics, it follows zero-order input. For example, oral drugs undergo first-order absorption upon administration and are eliminated through nonlinear pharmacokinetics.
In the case of subcutaneously administered drugs,...
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...