Headspace liquid-phase microextraction using ionic liquid as extractant for the preconcentration of
Cun-Ling Ye1, Qing-Xiang Zhou, Xin-Ming Wang
1School of Chemistry and Environmental Sciences, Henan Key Laboratory for Environmental Pollution Control, Henan Normal University, Xinxiang, Henan 453007, PR China.
Abstract:
A novel technique, high temperature headspace liquid-phase microextraction (HS-LPME) with room temperature ionic liquid (RTIL), 1-butyl-3-methylimidazolium hexafluorophosphate ([C4MIM][PF6]) as extractant, was developed for the analysis of dichlorodiphenyltrichloroethane (p,p'-DDT and o,p'-DDT) and its metabolites including 4,4'-dichlorodiphenyldichloroethylene (p,p'-DDE) and 4,4'-dichlorodiphenyldichloroethane (p,p'-DDD) in water samples by high performance liquid chromatography with ultraviolet detection. The parameters such as salt content, sample pH and temperature, stirring rate, extraction time, microdrop volume, and sample volume, were found to have significant influence on the HS-LPME. The conditions optimized for extraction of target compounds were as follows: 35% NaCl (w/v), neutral pH condition, 70 degrees C, 800 rpm, 30 min, 10 microL [C4MIM][PF6], and 25 mL sample solutions. Under the optimized conditions, the linear range, detection limit (S/N=3), and precision (R.S.D., n=6) were 0.3-30 microg L(-1), 0.07 microg L(-1), and 8.0% for p,p'-DDD, 0.3-30 microg L(-1), 0.08 microg L(-1), and 7.1% for p,p'-DDT, 0.3-30 microg L(-1), 0.08 microg L(-1), and 7.2% for o,p'-DDT, and 0.2-30 microg L(-1), 0.05 microg L(-1), and 6.8% for p,p'-DDE, respectively. Water samples including tap water, well water, snow water, reservoir water, and wastewater were analyzed by the proposed procedure and the recoveries at 5 microg L(-1) spiked level were in the range of 86.8-102.6%.
Related Concept Videos
High-Performance Liquid Chromatography: Elution Process
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Ion-Exchange Chromatography
Extraction: Advanced Methods
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process: