Related Experiment Video
Updated: Jul 12, 2026

Automated 90Sr Separation and Preconcentration in a Lab-on-Valve System at Ppq Level
Published on: June 6, 2018
Determination of 226Ra in aqueous solutions via sorption on thin films and alpha-spectrometry
D Karamanis1, K G Ioannides, K C Stamoulis
1Physics Department, The University of Ioannina, 45110 Ioannina, Greece. dkaraman@cc.uoi.gr
Abstract:
An improved spectrometric method to determine the 226Ra activity in aqueous solutions is described. The method involves two stages, a preconcentration stage of 226Ra sorption onto a thin manganese layer and a measurement stage using alpha-spectrometry. Manganese oxide thin films were prepared and characterized with X-ray diffraction (XRD) and X-ray fluorescence (XRF) analyses. The thin films were found to follow the XRD patterns and chemical formula of the K-birnessite layered exchanger. The preconcentration of radium was studied relative to the initial radium concentration, pH and salt concentrations. The preconcentration kinetics was studied as a function of manganese surface, solution volume and salt concentration. Extensive Monte Carlo calculations were performed to optimise the detection of alpha-particles. In this way, the thin film preparation procedure as well as the radium sorption and the measurement conditions were optimised and detection limits lower than 0.5 mBq L(-1) were obtained for 2d of procedure completion. The method was validated with IAEA standards and it was applied for the determination of 226Ra in bottled waters and also wastewaters from the major thermoelectric plant in Greece. Moreover, the 226Ra distribution coefficients (K(d)) of two differently prepared powder manganese oxides, a crystalline silicotitanate and an aluminium-pillared montmorillonite were determined by gamma-spectrometry. 226Ra sorption experiments on silicotitanate thin films were performed and improvements in resolution and reduction of exposure time were observed.
Related Concept Videos
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing nebulizer...
Atomic Emission Spectroscopy: Lab
Atomic Absorption Spectroscopy: Overview
When irradiated by EMR of a particular wavelength, these...
Atomic Emission Spectroscopy: Overview
Atomic Absorption Spectroscopy: Interference
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
Atomic Absorption Spectroscopy: Radiation and Light Sources
Two common narrow-range 'line' sources used in AAS are hollow-cathode lamps (HCLs) and...

