Related Experiment Video
Updated: Jul 12, 2026

Dried Blood Spots - Preparing and Processing for Use in Immunoassays and in Molecular Techniques
Published on: March 13, 2015
Evaluation of the Murex HIV Ag/Ab Combination assay when used with dried blood spots
V Lakshmi1, T Sudha, M Bhanurekha
1Department of Microbiology, Nizam's Institute of Medical Sciences, Punjagutta, Hyderabad, India. lgorthi@hotmail.com
Abstract:
This study evaluated the ability of the Murex HIV Ag/Ab Combination assay to detect human immunodeficiency virus (HIV) antibodies in 12 617 dried blood spots (DBSs) on filter paper. The assay had an overall sensitivity of 99.6% and a specificity of 99.9%. In view of its ability to detect p24 antigen and both HIV-1 and HIV-2 antibodies in samples collected in the form of DBSs, the Murex Ag/Ab Combination assay is suitable for use as a standard screening assay for seroprevalence studies, as well as for routine diagnostic use in clinical laboratories.