Related Experiment Video
Updated: Jul 12, 2026

Evaluation of Left Ventricular Structure and Function using 3D Echocardiography
Published on: October 28, 2020
Assessment of left ventricular dyssynchrony with real-time 3-dimensional echocardiography: comparison with Doppler
Masaaki Takeuchi1, Avrum Jacobs, Lissa Sugeng
1Department of Cardiology and Internal Medicine, Tane General Hospital, Osaka, Japan. masaaki_takeuchi@hotmail.com
Abstract:
We studied the usefulness and reproducibility of real-time 3-dimensional (3D) echocardiography (RT3DE) for evaluating left ventricular (LV) dyssynchrony, and compared its results with Doppler tissue image (DTI) indices. Full-volume RT3DE data sets and 2-dimensional DTI from apical window were obtained in 122 participants. Using fast 3D border detection software, time to minimum systolic volume (Tmsv) was semiautomatically calculated in each region from a 17-segment model. Several dyssynchrony indices were then calculated: Tmsv-16SD, the SD of Tmsv in 16 of 17 segments, excluding the apical cap; Tmsv-12SD, the SD of Tmsv of 6 basal and 6 middle segments; and Tmsv-6SD, the SD of Tmsv of 6 basal segments. These dyssynchrony indices of RT3DE were then compared with two dyssynchrony indices measured by DTI: time to peak systolic velocity (TTPV)-12SD, the SD of time to peak systolic velocity of 12 LV segments; and time to cross over point of temporal axis (TTCO)-12SD, the SD of time to crossover point of temporal axis. RT3DE data was quantitatively analyzed in 117 of 122 patients. Tmsv-16SD (35 +/- 34 milliseconds) was significantly longer compared with Tmsv-12SD (27 +/- 30 milliseconds, P < .001) or Tmsv-6SD (23 +/- 28 milliseconds, P < .001). Tmsv-16SD increased significantly with the severity of LV systolic dysfunction. Fair correlation was noted among TTPV-12SD, TTCO-12SD, and Tmsv-16SD (r = 0.71, r = 0.73) and between Tmsv-16SD and LV ejection fraction (r = 0.80). Concordance rate between TTPV-12SD and Tmsv-16SD for detecting LV dyssynchrony was 79%. The corresponding value between TTCO-12SD and Tmsv-16SD was 80%. In conclusion, Tmsv-16SD correlated well with DTI-derived LV dyssynchrony indices. In addition to LV remodeling, fast border detection RT3DE provides useful parameters for evaluating LV dyssynchrony.
Related Concept Videos
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for diagnosing...
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion, evaluates...
