Real-Time Cardiac Mapping with a Noninvasive Imageless Electrocardiographic Imaging System
Published on: April 11, 2025
The time interval from the initiation of the P-wave to the start of left atrial appendage ejection flow: does it
Mustafa Karaca1, Ozan Kinay, Cem Nazli
1Cardiology Department, Atakalp Heart Center, No: 16 Kahramanlar, Izmir, Turkey. mustafakaraca99@hotmail.com
Unlabelled:
Recurrence of atrial fibrillation is more common in patients with atrial conduction delay. In the present study, we evaluated whether findings obtained from transesophageal echocardiography (TEE), a semi-invasive method, correlate with those from an invasive method, electrophysiologic study (EPS), in measuring interatrial conduction time.
Methods And Results:
We compared two methods of calculating interatrial conduction time in a group of 33 patients. The origin of the P-wave on the surface electrocardiogram (ECG) was taken as the onset of atrial activation. The time interval from this point to the commencement of the left atrial appendage ejection flow (P-LAA) was measured by TEE. Meanwhile, simultaneous recordings of the left atrial appendage were obtained with a catheter positioned in the LAA, and an invasive interatrial conduction time was measured from the origin of the surface's earliest P-wave (I-IACT). The mean I-IACT (46.27 +/- 13.25 ms) correlated strongly with the mean P-LAA (49.91 +/- 12.72 ms; r = 0.839, P < 0.0001).
Conclusion:
The interatrial conduction time can be estimated with a relatively noninvasive method using P-LAA measurements. This technique can be applied widely in predicting AF recurrence, and appropriate therapy may be applied.
Related Concept Videos
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
The Cardiac Cycle
The Process
Electrical signals—sent from the sinoatrial (SA) node in the right atrial wall to the atrioventricular (AV) node between the right atrium and right ventricle—cause both atria to simultaneously contract. When the signal reaches the AV node, it pauses for approximately a tenth of a second, allowing the atria to contract and empty blood into the...
Conduction System of the Heart
This system relies on the unique properties of nodal and Purkinje cells:...
Conduction System of the Heart
The pacemaker cells are located in two primary nodes: the sinoatrial (SA) node and the atrioventricular (AV) node. The SA node pacemaker cells can autonomously depolarize, triggering an action potential that leads to the...
Electrocardiogram Fundamentals
An electrocardiogram (ECG) is a diagnostic tool for identifying cardiac conditions such as arrhythmias, conduction abnormalities, and myocardial ischemia.
Definition
An electrocardiogram (ECG) visualizes the heart's electrical activity by tracing the electrical movement associated with each heartbeat on a graph or monitor. As the heart beats, an electrical wave passes through it, correlating with the cardiac cycle events.
Parts of an ECG
An ECG utilizes electrodes on the skin to...
Cardiac Cycle
During the cardiac cycle, blood flow through the heart is regulated entirely by changing pressure gradients. This sequence of events begins with the heart in a state of total relaxation, known as mid-to-late diastole, during which blood passively flows from...