Corrections and clarifications

    Science (New York, N.Y.)
    |March 24, 1995
    PubMed

    Insights

    A correction is issued regarding a figure in a study on genetic factors influencing atrial natriuretic peptide and hypertension. The figure shows misaligned size bars in a Southern blot analysis.

    Area of Science:

    • Genetics
    • Cardiovascular Physiology
    • Molecular Biology

    Background:

    • The study investigates the relationship between atrial natriuretic peptide (ANP) levels and salt-sensitive hypertension.
    • Genetic factors are implicated in the regulation of ANP and blood pressure.
    • Previous research highlights the role of ANP in cardiovascular homeostasis.

    Purpose of the Study:

    • To report a figure correction for a study on genetic influences on ANP and hypertension.
    • To ensure accurate representation of Southern blot data.

    Main Methods:

    • Southern blot analysis was used to assess genetic variations.
    • Data visualization and figure preparation were conducted.

    Main Results:

    • A specific figure (ID, p. 680) in the report contains misaligned size bars.
    • The misaligned bars are in relation to dark bands on the Southern blot.

    Conclusions:

    • The correction ensures the integrity and accurate interpretation of the study's findings.
    • Precise data presentation is crucial for understanding genetic links to hypertension.

    Related Concept Videos

    Distance Corrections01:15

    Distance Corrections

    To achieve precise distance measurements, especially in surveying and construction, certain corrections must be applied to account for potential sources of error like the standardization errors, temperature variations, and slope adjustments.Standardization error emerges when measurement equipment undergoes changes, such as wear, repairs, or weather impacts. To address this, surveyors compare the equipment’s readings to a standard. This process identifies any deviation that might lead to...
    NMR Spectrometers: Resolution and Error Correction01:14

    NMR Spectrometers: Resolution and Error Correction

    When magnetic nuclei in a sample achieve resonance and undergo relaxation, the signal detected in NMR is an approximately exponential free induction decay. Fourier transform of an exponential decay yields a Lorentzian peak in the frequency domain. Lorentzian peaks in an NMR spectrum are defined by their amplitude, full width at half maximum, and position, where the peak width is governed by the spin-spin relaxation time alone. In real experiments, however, the applied magnetic field is rendered...
    Accuracy, limits, and approximation01:28

    Accuracy, limits, and approximation

    Accuracy, limits, and approximations are common in many fields, especially in engineering calculations. These concepts are imperative for ensuring that a given value is as close as possible to its true value.
    Accuracy is defined as the closeness of the measured value to the true or actual value. In engineering mechanics, repeated measurements are taken during theoretical or experimental analyses to ensure that the result is precise and accurate.
    The accuracy of any solution is based on the...
    Types of Errors: Detection and Minimization01:12

    Types of Errors: Detection and Minimization

    Error is the deviation of the obtained result from the true, expected value or the estimated central value. Errors are expressed in absolute or relative terms.
    Absolute error in a measurement is the numerical difference from the true or central value. Relative error is the ratio between absolute error and the true or central value, expressed as a percentage.
    Errors can be classified by source, magnitude, and sign. There are three types of errors: systematic, random, and gross.
    Systematic or...
    Contaminants and Errors01:16

    Contaminants and Errors

    Effective sample preparation is crucial for accurate and reliable laboratory analysis. During this process, two significant sources of error can arise: concentration bias from improper sample splitting and contamination caused by methods used to reduce particle size, such as grinding or homogenization. Identifying and minimizing these potential errors is crucial to ensuring the validity of the analysis.
    Another key consideration is determining the appropriate number of samples required to...
    Errors and Mistakes in Surveying01:19

    Errors and Mistakes in Surveying

    Errors and mistakes in surveying refer to inaccuracies in measurements and data recording. The errors are deviations from the actual value caused by human sensory limitations, equipment flaws, or environmental effects. These errors are typically unintentional and can result from the inherent imperfections in the instruments used, atmospheric conditions, or the observer’s inability to perceive exact measurements. On the other hand, mistakes are caused by the surveyor's lack of attention,...