Related Experiment Video
Updated: Jul 12, 2026

Variations on Negative Stain Electron Microscopy Methods: Tools for Tackling Challenging Systems
Published on: February 6, 2018
Negative staining across holes: application to fibril and tubular structures
1Institute of Zoology, University of Mainz, D-55099 Mainz, Germany. rharris@mail.uni-mainz.de
Abstract:
The negative staining technique, when used with holey carbon support films, presents superior imaging conditions than is the case when samples are adsorbed to continuous carbon films. A demonstration of this negative staining approach is presented, using ammonium molybdate in combination with trehalose, applied to several fibrillar and tubular samples. Fibrils formed from the amyloid-beta peptide and the protease inhibitor pepstain A spread very well unsupported across holes and the different polymorphic fibril forms can be readily assessed. However, tubular forms of amyloid-beta have a tendency to be flattened, due to surface tension forces prior to and during specimen drying. Sub-fibril assembly forms and D-banded rat tail type 1 collagen fibres are presented. The air-dried collagen images produced are shown to contain almost as much detail as those obtainable by cryo-negative staining. Fragile DNA and DNA-protein nanotubes are also shown to yield superior quality images to those produced on continuous carbon films. The iron-storage protein, frataxin, creates elongated oligomeric assemblies, containing bound ferrihydrite microcrystals. The iron particles within these flexuous oligomers can be defined in the presence of ammonium molybdate, but they are more readily demonstrated if the frataxin is spread across holes in the presence of trehalose alone. The samples used here serve to show the likely benefit obtainable from negative staining across holes for a range of other fibrillar and tubular samples in biology, medicine and nanobiotechnology.
More Related Videos
08:01Visualizing Proteins and Macromolecular Complexes by Negative Stain EM: from Grid Preparation to Image Acquisition
Published on: December 22, 2011
09:37Optimized Negative Staining: a High-throughput Protocol for Examining Small and Asymmetric Protein Structure by Electron Microscopy
Published on: August 15, 2014
Related Concept Videos
Special Staining Techniques
Fixation and Sectioning
The simplest type of preparation is the wet mount, in which the specimen is placed in a drop of liquid on the slide. A liquid specimen can be directly deposited on the slide using a dropper. Solid specimens, such as skin scraping, can be placed on the slide before adding a drop of liquid to prepare the wet mount. Sometimes the liquid is simply water, but stains are often added...
Differential Staining Technique
Immunogold Electron Microscopy