Increasing Pulmonary Artery Pulsatile Flow Improves Hypoxic Pulmonary Hypertension in Piglets
Published on: May 11, 2015
[The assessment of pulmonary arterial pressure by pulsed Doppler in patients with obstructive pneumopathy]
A Corinaldesi1, M Zompatori, C Sturani
1Istituto di Radiologia, Università, Policlinico S. Orsola, Bologna.
Abstract:
The severity of pulmonary arterial hypertension can be assessed by duplex-Doppler echocardiography, a subxiphoid approach and a general-purpose duplex device. Normally, the peak Doppler flow velocity occurs in midsystole and the flow profile is parabolic (bullet-like). In pulmonary arterial hypertension, changes in vascular compliance cause maximal acceleration of blood in early systole, with shortening of pulmonary acceleration time (AcT, or time to peak velocity). In the more severe cases, a midsystolic notching is visible, related to rapid deceleration of blood flow, followed by a brief secondary increase in velocity in the late systole. We studied 19 adult patients with chronic obstructive pulmonary disease with duplex-Doppler examination, with a subxiphoid approach and right heart catheterization. The study was diagnostic in all cases with Doppler recordings of good quality. An relationship was found between AcT and pulmonary mean or systolic arterial pressure at rest. An evident accurate prediction of pulmonary arterial pressure in emphysematous patients is possible by means of pulsed Doppler, also in case of low-level hypertension. We believe this method to be a simple and reliable adjunct to the non-invasive work-up of emphysematous patients and to represent a good alternative to the classical parasternal approach, which is often not feasible in these patients.
More Related Videos
07:09Assessment of Pulmonary Capillary Blood Volume, Membrane Diffusing Capacity, and Intrapulmonary Arteriovenous Anastomoses During Exercise
Published on: February 20, 2017
08:57Pulsed Wave Doppler Assessment of Diastolic Dysfunction in the ZSF-1 Rat Model of Pulmonary Hypertension Due to Left Heart Disease
Published on: May 22, 2026
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Measurement of Blood Pressure
Pulse
The pulse serves as a clinical indicator...
Chronic Obstructive Pulmonary Disease-IV: Assessement and Diagnostic Studies
Medical History
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation