Evaluating the Effects of Different Polishing Methods on Color Stability of Dental Restorations in Pediatric Dentistry
Published on: June 6, 2025
Evaluation of a standard shade guide for color change after disinfection
Randall M Pohjola1, Steven T Hackman, William D Browning
1Veterans Administration Hospital, Augusta, GA 30904, USA. randall.pohjola@va.gov
Objective:
To determine if surface disinfectants cause a change in the shade perception of a standard Classic Vitapan shade guide.
Method And Materials:
Consistency in shade selection for dental restorations involves many factors, and one of the most important is the shade tabs used in the selection process. Ten shade tabs each of shades B2, D2, C1, and A3.5 were selected from the Classic Vitapan shade guide (Vident). All tabs were measured with the EasyShade shade device (Vident) at baseline. Three tabs of each shade were set aside as controls. The other 7 tabs of each shade were treated with the surface disinfectant Cavicide (Metrex Research) for 480 cycles to simulate a year's usage. After each 480 cycles, all the tabs were again measured with the EasyShade. This process was repeated to simulate 2 and 3 years of use.
Results:
The data were analyzed to calculate the delta E 2000 for any change. A statistically significant increase was observed in the value (L*) and chroma (C*) after 2 and 3 years of simulated treatments. These changes were not perceptible to the clinician.
Conclusions:
The authors suggest that 1 standard shade guide be set aside to compare against those in clinical use to determine when they should be replaced.
Related Concept Videos
Indicators
Cleaning, Sterilization, and Disinfection
Cleaning
The cleaning process usually involves using water with detergents or enzymatic cleaner and removing foreign material from objects and surfaces, including organic material such as body fluids or inorganic material like soil. Cleaning is performed before high-level disinfection and sterilization because foreign materials on the cover of the devices interfere with process...
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a result, EDTA...