A framework to investigate drug release variability arising from hypromellose viscosity specifications in controlled

Shawn A Mitchell1, Karen M Balwinski

  • 1Water Soluble Polymers, The Dow Chemical Company, Midland, Michigan 48674, USA. samitchell@dow.com

Related Concept Videos

Factors Influencing Drug Absorption: Pharmaceutical Parameters01:28

Factors Influencing Drug Absorption: Pharmaceutical Parameters

Solid dosage forms such as tablets and capsules undergo rigorous manufacturing processes to ensure stability and effectiveness. Their dissolution and absorption properties are influenced significantly by the choice of excipients (inactive ingredients that serve various roles in the formulation), and the methodology applied during production. The manufacturing parameters, such as compression force and granulation techniques, significantly affect dissolution rates. Elevated compression forces...
Modified-Release Drug Delivery Systems: Drug Release Characteristics01:22

Modified-Release Drug Delivery Systems: Drug Release Characteristics

Drug release from modified-release dosage forms is designed to achieve specific therapeutic effects by controlling the rate and extent of drug release. The classification of these drug release systems is based on key pharmacokinetic assumptions: drug disposition follows first-order kinetics, drug release is the rate-limiting step in absorption, and the released drug is rapidly and completely absorbed.There are four major models of drug release patterns. The first model is the slow zero-order...
In Vitro Drug Dissolution: Compendial Testing Models I01:13

In Vitro Drug Dissolution: Compendial Testing Models I

Compendial dissolution methods are standardized procedures defined by pharmacopeias to evaluate the rate at which a drug dissolves in a specific medium. These methods ensure batch-to-batch consistency, enable quality control, and support the prediction of drug bioavailability. They are critical for both immediate and modified-release drug products.The apparatuses used for dissolution testing differ in their design and mechanical function, but all aim to simulate the physiological environment of...
In Vitro Drug Dissolution: Compendial Testing Models II01:09

In Vitro Drug Dissolution: Compendial Testing Models II

Various dissolution methods are utilized to assess a drug’s dissolution rate, including the flow-through cell, paddle-over-disk, cylinder, and reciprocating disk methods.The flow-through cell apparatus (USP (United States Pharmacopeia) method 4) comprises a reservoir for the dissolution medium and a pump that propels the medium through the cell containing the test sample. This method is crucial for assessing modified-release dosage forms with minimally soluble active ingredients, maintaining...
Modified-Release Drug Delivery Systems: Rate-Programmed II01:19

Modified-Release Drug Delivery Systems: Rate-Programmed II

Rate-programmed drug delivery systems release drugs in a controlled manner to maintain therapeutic levels. Three main designs include reservoir, matrix, and hybrid systems.Reservoir systems consist of a drug core enclosed within a membrane that controls drug release. In non-swelling reservoir systems, polymers like ethyl cellulose or polymethacrylates are used. These do not hydrate in aqueous media and control release through membrane thickness, porosity, or insolubility. This type includes...
Drug Dissolution: Requirements and Profile Comparison01:14

Drug Dissolution: Requirements and Profile Comparison

The acceptance criteria for dissolution profile data are anchored in Q values, representing the percentage of drug dissolved within a specified period. This assessment unfolds in three stages:First Stage: The test passes if all six drug dosage units are equal to or greater than Q plus 5%; otherwise, the sample proceeds to the second stage.Second Stage: The average of twelve units must be equal to or greater than Q, with no unit falling below Q - 15% to pass; if not, it progresses to the final...