Evaluation of the Reynolds Pathfinder II system for 24 h heart rate variability analysis
1University Department of Cardiology, Skejby Sygehus, Arhus, Denmark.
Abstract:
Heart rate variability (HRV) in 24-h Holter recordings is normally determined using commercially available Holter equipment. However, short-term speed variations in tape-based Holter systems have not been thoroughly investigated and recommendations for speed control are vague. In this study, overall accuracy and precision of RR interval measurement was assessed for two types of tape recorder replayed on the same Reynolds Pathfinder II system. Artificial QRS complexes spaced at exact intervals were recorded simultaneously by the two recorders. In addition, records of 118 healthy subjects were evaluated for false-positive normal-normal intervals. During replay, digital output from the pathfinder was processed by a locally developed personal computer-based HRV system. Using the recorded crystal generated timing track (TT) for speed control and the TT dependent speed surveyor (SS), set to allow speed errors up to +/- 3.1%, mean RR per 5 min.h-1.24 h-1, for test tapes, corresponded exactly to true RR, for both recorders. Beat-to-beat variation, for 1000 ms test intervals, calculated as standard deviation (SD) and root mean square of successive differences (RMSSD) was 3 ms, 3 ms versus 5 ms, and 8 ms for Oxford and Tracker tapes respectively. No difference between sequential intervals exceeded +/- 10 ms versus +/- 20 ms for Oxford and Tracker respectively. Reproducibility of mean RR and HRV parameters for patient records, expressed as a coefficient of variation, was 0.1-1.7%. False positive normal-normal intervals greater than 2.3 s, due to artifacts, were found in 99 of 118 records, and these increased mean SD and RMSSD values significantly, whereas percent successive RR interval differences greater than 50 ms were unaffected. A crystal generated TT (60/16 Hz) and an SS allowing a maximum error of +/- 3.1%, together correct speed during recording and replay to a degree that is acceptable for HRV analysis. A simple estimate of HRV counts of successive RR interval differences greater than 50 ms is a reliable parameter as it is relatively insensitive to artifact.
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...
Factors Influencing Heart Rate
Let us explore the significant factors affecting heart rate, including age, body temperature, posture, acute pain, chemical influences,...
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Holter Monitor: 24-Hour Monitoring
Dysrhythmias V: Evaluating Dysrhythmias