Related Experiment Video
Updated: Jul 11, 2026

Halogenated Agent Delivery in Porcine Model of Acute Respiratory Distress Syndrome via an Intensive Care Unit Type Device
Published on: September 24, 2020
Comparison of the Effects of Sevoflurane and Halothane on Arterial Oxygenation during One Lung Ventilation
P Chari1, Y K Batra, S S Murthy
1Department of Anaesthesiology, Postgraduate Institute of Medical Education and Research, Chandigarh, India.
Abstract:
We investigated the effect of halothane and sevoflurane on oxygenation during one lung ventilation (OLV) in 24 patients undergoing elective thoracic procedures. After induction with thiopentone, 4-5 mg/kg and morphine 0.1 mg/kg, suxamethonium 2mg/kg was administered to facilitate tracheal intubation with a double lumen tube. Anaesthesia was maintained with 1.5-3% sevolurane (group 1, n = 12) or 1.1.5% halothane (group 2, n = 12) in 02 with N20 (1:1) and pancuronium bromide. Arterial blood gases were recorded before surgery in the lateral position with two lung ventilation (2LV), 10, 20 and 30 minutes after beginning of one lung ventilation. Morphine and endtidal inhalational anaesthetic concentration were titrated to desired anaesthetic depth and haemodynamic variables. Systolic blood pressure (SBP), diastolic blood pressure (DBP), heart rate (HR) and central venous pressure (CVP) were measured during the study period. In both the groups there was a significant decrease of PaO2 apparent at 10 minutes after initiation of OLV. Thereafter PaO2 remained stable throughout the study period in both the groups. It is concluded that oxygenation did not differ significantly with either sevoflurane or halothane during OLV. It is also concluded that decrease in oxygenation with OLV is complete by 10 minutes of its initiation.
Related Concept Videos
Inhalational Anesthetics: Overview
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.
Acute Respiratory Failure-II
The underlying physiological abnormalities that contribute to hypoxemic respiratory failure include:
Stages of General Anesthesia
General Anesthesia: Overview
General anesthesia induces unconsciousness in the whole body, while the others target specific areas or sensations. It is administered to minimize adverse effects, maintain...