Related Experiment Video
Updated: Jul 11, 2026

X-ray Dose Reduction through Adaptive Exposure in Fluoroscopic Imaging
Published on: September 11, 2011
Optimising the use of computed radiography in pediatric chest imaging
R Sanchez Jacob1, E Vano-Galvan, E Vano
1Pediatric Radiology, C. S. Mott Children's Hospital, F3503, 1500 E. Medical Center Drive, Ann Arbor, MI 48109-0252, USA. ramonsan@umich.edu
Abstract:
The objective of this study was to analyze image quality of chest examinations in pediatric patients using computed radiography (CR) obtained with a wide range of doses to suggest the appropriate parameters for optimal image quality. A sample of 240 chest images in four age ranges was randomly selected from the examinations performed during 2004. Images were obtained using a CR system and were evaluated independently by three radiologists. Each image was scored using criteria proposed by the European Guidelines on Quality Criteria in Pediatrics. Mean global scoring and scoring of individual criteria more sensitive to noise were used to evaluate image quality. Agfa dose level (DL) was in the range 1.20 to 2.85. It was found that there was not significant correlation (R < 0.5) between image quality and DL for any of the age ranges for either global score or for individual criteria more related to noise. The mean value of DL was in the ranges 1.9-2.1 for the four age bands. From this study, a DL value of 1.6 is proposed for pediatric CR chest imaging. This could yield a reduction of approximately a factor of 2.5 in mean patient entrance surface doses.
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Radiological Investigation I: X-ray and CT
X-ray Imaging
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies III: Computed Tomography