Long-term Blood Pressure Measurement in Freely Moving Mice Using Telemetry
Published on: May 17, 2016
Master blood pressure variation in office, by self, and in sleep recordings
1Stress Clinic, University of Uppsala, Sweden. karel.pavek@home.se
Abstract:
Variation inherent to each session in any recording situation has to be mastered to obtain informative mean values and differences. Variation due to time trend and unsteady consecutive readings versus inter-arm variations in blood pressure (BP) in the operator-initiated, self-initiated, and sleep recordings were studied by oscillometry. They were small in operator-initiated recordings, increased in self-recordings, and were paramount in sleep. A passive supine patient and simultaneous recordings with cuffs placed in equal horizontal positions are essential conditions for the estimation of a real mean inter-arm difference. The relative variation of pulse pressure (PP), compared with other components, was largest within each situation. Most of the systolic BP (SBP)/diastolic BP (DBP) variation in sleep was due to unequal vertical cuff distances to the heart level. Only sleep PP was independent of the vertical position of cuffs. A plot of inter-arm differences can visualize systematic errors in sequences of sleep SBP/DBP. As is well known, every doubling of variation (SD) requires quadrupling the number of independent recordings in order to retain the same size of confidence interval (CI) for a mean value.
Related Concept Videos
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Measurement of Blood Pressure
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Errors occurring during blood pressure monitoring
Several factors...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of blood pressure in brachial artery(two-step method)