Theoretical and practical considerations on detection performance of time domain, Fourier domain, and swept source
1Brigham and Women's Hospital, Department of Orthopedic Surgery, 75 Francis Street, Boston, Massachusetts 02115, USA.
Abstract:
Optical coherence tomography (OCT) based on spectral interferometry has recently been examined, with authors often suggesting superior performance compared with time domain approaches. The technologies have similar resolutions and the spectral techniques may currently claim faster acquisition rates. Contrary to many current opinions, their detection parameters may be inferior. The dynamic range and signal-to-noise ratio (SNR) correlate with image penetration, the contrast as a function of depth. This work examines the theoretical sensitivity, dynamic range, and SNR of the techniques, within the practical limits of optoelectronics, taking into account often ignored or misunderstood classical factors that affect performance, such as low frequency noise, analog to digital (AD) conversion losses, and methods for potentially improving sensitivity, including fast laser sweeping. The technologies are compared relative to these parameters. While Fourier domain OCT has some advantages such as signal integration, it appears unlikely that its disadvantages can ultimately be overcome for nontransparent tissue. Ultimately, time-domain (TD)-OCT appears to have the superior performance with respect to SNR and dynamic range. This may not be the case for transparent tissue of the eye. Certain positive aspects of swept source OCT leave the possibility open that its performance may approach that of (TD)-OCT in nontransparent tissue.
More Related Videos
14:21Optical Frequency Domain Imaging of Ex vivo Pulmonary Resection Specimens: Obtaining One to One Image to Histopathology Correlation
Published on: January 22, 2013
08:50Longitudinal Morphological and Physiological Monitoring of Three-dimensional Tumor Spheroids Using Optical Coherence Tomography
Published on: February 9, 2019
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Biological Samples with Optical Microscopy
In optical microscopy, the specimen to be viewed is placed on a glass slide and clipped on the stage...