MIRD continuing education: Bystander and low dose-rate effects: are these relevant to radionuclide therapy?
George Sgouros1, Susan J Knox, Michael C Joiner
1School of Medicine, Johns Hopkins University, Baltimore, Maryland, USA. gsgouros@jhmi.edu
Abstract:
Bystander and low-dose-rate effects influence the dose-response relationship in a manner not predicted by current dosimetric methodologies. Radiation-induced bystander effects refer to biologic responses in cells that are not traversed by an ionizing radiation track and, thus, not subject to direct energy deposition; that is, the responses occur in nonirradiated cells. Low-dose-rate hypersensitivity effects have been documented as a reduction in the survival of cells irradiated at dose rates of 0.1-1.0 Gy/h, with total doses ranging from 1.5 to 5 Gy. For humans undergoing external radiotherapy, evidence of bystander events has been observed in the form of abscopal effects, wherein irradiation of one portion of the anatomy affects a portion outside the radiation field, whereas low-dose-rate hypersensitivity has not been described. In this report, the historical literature is briefly reviewed, key experiments are summarized, and current understanding of the factors thought to be involved in the bystander and low-dose-rate effects is conveyed. The mechanisms associated with these events are still being investigated, and questions remain on their impact in radionuclide therapy. Although current findings do not yet sufficiently justify changing traditional dose estimates used to predict the outcomes of radionuclide therapy, it is important to appreciate the potential importance of these effects and to begin revising methods to reflect the emerging empiric and mechanistic knowledge.
Related Concept Videos
Biological Effects of Radiation
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Radiological Investigation I: X-ray and CT
Isotopes and Radioisotopes
An isotope containing more...
Absorption of Radiation
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...