Comparison of Agreement and Accuracy using Binocular Wavefront Optometer with Autorefractor and Phoropter
Published on: September 16, 2025
Use of adaptive optics to determine the optimal ocular spherical aberration
Patricia A Piers1, Silvestre Manzanera, Pedro M Prieto
1Department of Applied Research, AMO Groningen BV, Groningen, The Netherlands. patricia.piers@amo-inc.com
Purpose:
To explore the impact of spherical aberration (SA) on contrast sensitivity using an adaptive optics vision simulator to determine the optimal amount of SA to include in customized corrections of wavefront aberrations.
Setting:
Laboratorio de Optica, Universidad de Murcia, Murcia, Spain, and AMO Groningen BV, Groningen, The Netherlands.
Methods:
An adaptive optics vision simulator consisting of a wavefront sensor, a 97-segmented deformable mirror to induce and correct aberrations of the eye, and a visual testing path was constructed for this study. The deformable mirror allows the effective ocular wavefront aberration to be manipulated and the resulting visual performance to be measured simultaneously. Subjective measurements of contrast sensitivity at 15 cycles per degree were performed with a 4.8 mm pupil in 5 subjects with different levels of naturally occurring SA. Contrast sensitivity was measured when SA values of -0.09 microm, 0.0 microm, 0.09 microm, and 0.182 microm were induced when the other natural aberrations of the eye were present, when the aberrations were corrected, and at defocus values of +/-0.25 diopter (D) and +/-0.50 D.
Results:
Subjects experienced peak contrast sensitivity performance with varying levels of SA when their natural aberrations were present; however, average contrast performance peaked at 0 mum of SA. When all higher-order aberrations were corrected, all 5 subjects' peak performance occurred at 0 microm of SA.
Conclusions:
The adaptive optics vision simulator reduced the root-mean-square wavefront aberration of the eye by up to a factor of 4 and allowed noninvasive testing of the visual performance resulting from any ocular wavefront aberration introduced by customized correction procedures. This study showed that, on average, contrast performance peaked when SA was completely corrected.