Related Experiment Video
Updated: Jul 11, 2026

Dual Test Gas Pulmonary Diffusing Capacity Measurement During Exercise in Humans Using the Single-Breath Method
Published on: February 2, 2024
Standardization of the single-breath diffusing capacity in a multicenter clinical trial
Robert A Wise1, John G Teeter, Robert L Jensen
1Johns Hopkins University School of Medicine, Baltimore, MD, USA. rwise@jhmi.edu
Standardizing lung diffusing capacity for carbon monoxide (DLCO) measurements in multicenter trials is feasible. This study achieved high-quality DLCO data collection, comparable to spirometry, for inhalable insulin safety assessments.
Area of Science:
- Pulmonary Medicine
- Clinical Trials
- Diabetes Research
Background:
- Multicenter trials face challenges in standardizing single-breath diffusing capacity of the lung for carbon monoxide (DLCO) measurements due to variability in equipment and training.
- Standardized DLCO measurement is crucial for safety assessments of new therapies like inhalable insulin.
Purpose of the Study:
- To assess the feasibility and reliability of a standardized methodology for single-breath DLCO measurements in a multicenter clinical trial setting.
- To ensure high-quality DLCO data collection for the safety assessment of inhaled human insulin in type 1 diabetes patients.
Main Methods:
- An open-label, 24-week, parallel-group study involving participants with type 1 diabetes receiving inhaled or subcutaneous insulin.
- Standardization involved uniform instrumentation, centrally trained coordinators, and centralized data monitoring with rapid feedback on test quality.
- Single-breath DLCO was monitored using the standardized methodology throughout the study.
Main Results:
- Over 11,000 DLCO efforts were completed across 33 sites by 226 participants.
- 75.2% and 95.5% of testing sessions yielded two acceptable DLCO efforts with variation < 1 and 2 mL/min/mm Hg, respectively.
- The root mean square intrasubject coefficient of variation in DLCO was 6.01% at the end of the study.
Conclusions:
- The implemented standardized methodology enables the collection of high-quality single-breath DLCO data in multicenter clinical trials.
- The reliability of the standardized DLCO measurements is comparable to that of spirometry.
- This approach facilitates precise safety assessments in trials involving new inhaled medications.
More Related Videos
Related Concept Videos
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...
Pulmonary Function Tests
Pulmonary Function Tests are crucial diagnostic tools for assessing respiratory function, particularly in patients with chronic respiratory disorders. They comprehensively evaluate lung volumes, ventilatory function, breathing mechanics, diffusion, and gas exchange. These tests help diagnose pulmonary diseases and play a significant role in monitoring disease progression, evaluating disability, and assessing response to therapy.
PFTs involve using a spirometer, a...
Respiratory Capacities
One key metric is the Inspiratory Capacity (IC), which represents the maximum amount of air that can be inhaled with full effort. IC is calculated by summing the tidal volume and inspiratory reserve volume, typically ranging from 2.4 to 3.6 liters.
The Functional Residual Capacity (FRC) represents the air in the...
Chronic Obstructive Pulmonary Disease-IV: Assessement and Diagnostic Studies
Medical History
Respiratory Volumes and Capacities I
Bioavailability Study Design: Single Versus Multiple Dose Studies

