Background:
The optimal left ventricle (LV) pacing site for cardiac resynchronization therapy (CRT) has been investigated, but less is known about the optimal site in the right ventricle (RV). The present study examined whether electrical resynchronization guided by electroanatomical mapping (CARTO) results in mechanical resynchronization.
Methods And Results:
The study group included 13 patients indicated for CRT: 10 with nonischemic cardiomyopathy, 2 with ischemic cardiomyopathy and 1 with cardiac sarcoidosis, (mean LV ejection fraction: 32+/-10%). CARTO of the RV septum was performed to identify the site with the most delayed conduction time during LV pacing. Hemodynamic measurements were performed during conventional biventricular pacing with the RV apex and LV (C-BVP) and during biventricular pacing with the most delayed site of the RV (d-RV) and LV (D-BVP). Lead placement at 15 coronary sinus veins was examined in the 13 patients. During pacing from anterolateral veins (n=2), the d-RV was the RV apex (RVA) in 1 patient and the mid-septum in the other. During pacing from lateral veins (n=9), the d-RV comprised the RVA (n=3), the mid-septum (n=5), and the right ventricular outflow tract (RVOT) (n=1). During pacing from the posterolateral veins (n=3), the d-RV was the RVOT in all cases. In 11 of 15 sites, d-RV differed from conventional RVA. Compared with C-BVP, D-BVP produced a significant improvement in LV dp/dt. Furthermore, RV mid-septum and LV pacing markedly increased LV dp/dt and pulse pressure (PP), but RVOT and LV pacing did not. D-BVP vs C-BVP: %LV dp/dt 30+/-20 and 15+/-15%, p<0.05; RV mid-septum and LV pacing vs C-BVP: %LV dp/dt 35+/-20 and 10+/-15%, p<0.02, and vs PP 33+/-20 and 10+/-29 mmHg, p<0.02.
Conclusions:
For pacing from the LV lateral vein, potential improvement of cardiac performance compared with that by conventional RVA placement may be realized with concomitant pacing from the d-RV (mid-septum).
More Related Videos
06:57Ablation of Ischemic Ventricular Tachycardia Using a Multipolar Catheter and 3-dimensional Mapping System for High-density Electro-anatomical Reconstruction
Published on: January 31, 2019
09:13Remote Magnetic Navigation for Accurate, Real-time Catheter Positioning and Ablation in Cardiac Electrophysiology Procedures
Published on: April 21, 2013
Related Concept Videos
Cardiac Catheterization II: Right Heart Catheterization
Electrocardiogram Fundamentals
An electrocardiogram (ECG) is a diagnostic tool for identifying cardiac conditions such as arrhythmias, conduction abnormalities, and myocardial ischemia.
Definition
An electrocardiogram (ECG) visualizes the heart's electrical activity by tracing the electrical movement associated with each heartbeat on a graph or monitor. As the heart beats, an electrical wave passes through it, correlating with the cardiac cycle events.
Parts of an ECG
An ECG utilizes electrodes on the skin to...