Related Experiment Video
Updated: Jul 11, 2026

A Postoperative Evaluation Guideline for Computer-Assisted Reconstruction of the Mandible
Published on: January 28, 2020
[Three-dimensional finite element analysis of three conjunctive methods of free iliac bone graft for established
Dong Wang1, Zhuang-qun Yang, Xiao-yi Hu
1Dept. of Oral and Maxillofacial Surgery, Xi'an Jiaotong University, Xi'an 710002, China.
Objective:
To analyze the stress and displacement distribution of 3D-FE models in three conjunctive methods of vascularized iliac bone graft for established mandibular body defects.
Methods:
Using computer image process technique, a series of spiral CT images were put into Ansys preprocess programe to establish three 3D-FE models of different conjunctions.
Results:
The three 3D-FE models of established mandibular body defects by vascularized iliac bone graft were built up. The distribution of Von Mises stress and displacement around mandibular segment, grafted ilium, plates and screws was obtained.
Conclusion:
It may be determined successfully that the optimal conjunctive shape be the on-lay conjunction.