Related Experiment Video
Updated: Jul 11, 2026

Facile Preparation of Ultrafine Aluminum Hydroxide Particles with or without Mesoporous MCM-41 in Ambient Environments
Published on: May 11, 2017
ET-AAS determination of aluminium in dialysis concentrates after continuous flow solvent extraction
J Komárek1, R Cervenka, T Růzicka
1Department of Analytical Chemistry, Masaryk University, Kotlárská 2, CZ-611 37 Brno, Czech Republic.
Abstract:
Conditions of a continuous flow extraction (CFE) of aluminium acetylacetonate in acetylacetone and aluminium 8-hydroxyquinolinate into methylisobutylketone (lengths of reaction and extraction coils, flow rates of aqueous and organic phases and their flow rate ratio, pH of aqueous phase, lengths of coils for transport of aqueous and organic phases and effect of salts) were studied. The analytical signal of the aluminium chelates present in the organic phase was measured at 309.3 nm using atomic absorption spectrometry with electrothermal atomization (ET-AAS) at the flow rate ratio F aq/F org=3 for aqueous and organic phases. The five points calibration curves were linear (R2 0.9973 and 0.9987) up to 21 microgl(-1) Al with the limits of detection of 0.3 microgl(-1) and the recovery 100+/-2% and precision of 3% at 2-10-fold dilution of the dialysis concentrates. The acetylacetonate method was applied to the determination of aluminium in real dialysis concentrates. Aluminium in concentrations 5-6 microgl(-1) (R.S.D.s 5-10% in real samples) were found and the results were in the very good agreement with those obtained by an ET-AAS using preconcentration of Al(III) on a Spheron-Salicyl chelating sorbent (absolute and relative differences were under 0.4 microgl(-1) and 8.2%, respectively).
More Related Videos
08:56Detection of Regulated Ergot Alkaloids in Food Matrices by Liquid Chromatography-Trapped Ion Mobility Spectrometry-Time-of-Flight Mass Spectrometry
Published on: November 22, 2024
06:10Extraction of Structural Extracellular Polymeric Substances from Aerobic Granular Sludge
Published on: September 26, 2016
Related Concept Videos
Dialysis
Extraction: Advanced Methods
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing nebulizer...
Extracorporeal Removal of Drugs: Peritoneal Dialysis and Hemodialysis
Determination of Multiple Dosing Parameters: Steady-State, Minimum and Maximum Concentrations
Extracorporeal Removal of Drugs: Hemoperfusion and Hemofiltration