Related Experiment Video
Updated: Jul 11, 2026

The Nijmegen Hemostasis Assay: Simultaneous Fluorogenic Measurement of Thrombin and Plasmin Generation in a Single Well
Published on: February 27, 2026
Thrombin generation assay and viscoelastic coagulation monitors demonstrate differences in the mode of thrombin
Kenichi A Tanaka1, Fania Szlam, He Ying Sun
1Department of Anesthesiology, Emory University School of Medicine, Atlanta, Georgia. USA. kenichi.tanaka@emoryhealthcare.org
Background:
Coagulation tests, such as activated partial thromboplastin time and activated clotting time, are used to monitor the effects of unfractionated heparin and the direct thrombin inhibitor, bivalirudin. These tests reflect only the initial phase of blood clotting, when <5% of thrombin has been formed. In this study, we sought to determine if similar increases in activated partial thromboplastin time or activated clotting time due to heparin or bivalirudin would reflect the same degree of inhibition of thrombin formation.
Methods:
Thrombin formation was evaluated in platelet-poor plasma activated in the presence of heparin (0-5 U/mL) or bivalirudin (0-30 microg/mL) using a thrombin generation assay (Thrombinoscope). Prothrombin activation was measured by prothrombin fragment 1.2 (F1.2) formation. Thrombus formation was further evaluated in kaolin-activated whole blood samples containing heparin (1.5 or 2.5 U/mL) or bivalirudin (12.5 or 25 microg/mL) using Sonoclot and thromboelastography.
Results:
Based on the Thrombinoscope results, increasing concentrations of bivalirudin and heparin progressively delayed the onset of thrombin formation, but only heparin dose-dependently decreased the amount of thrombin generated. Heparin and bivalirudin delayed the onset of F1.2 formation, but there was no difference in peak F1.2 levels between bivalirudin and non-anticoagulated samples (206 +/- 28.2 vs 182 +/- 23.9 nmol/L, P = 0.09). In heparinized samples, F1.2 levels were significantly lower (75.7 +/- 29.8 nmol/L, P < 0.05) than controls. Heparin and bivalirudin prolonged the onset of clotting on viscoelastic monitors, but only heparin decreased the rate of thrombus formation.
Conclusion:
Thrombus formation kinetics differs between heparin and bivalirudin despite similar prolongation of clotting test values.
Related Concept Videos
Anticoagulant Drugs: Low-Molecular-Weight Heparins
Venous Thrombosis III: Interprofessional Care
Anticoagulant Drugs: Vitamin K Antagonists and Direct Oral Anticoagulants
Warfarin, a prominent vitamin K antagonist family member, exerts its effect by inhibiting the enzyme VKORC1 (vitamin K epoxide reductase complex 1). By hindering this enzyme, warfarin...
Venous Thrombosis II: Clinical Manifestations and Diagnostic Studies
Clot Retraction and Fibrinolysis