Related Experiment Video
Updated: Jul 11, 2026

Three-Dimensionally Printed Microfluidic Cross-flow System for Ultrafiltration/Nanofiltration Membrane Performance Testing
Published on: February 13, 2016
Comparison of mixed liquor filterability measured with bench and pilot-scale membrane bioreactors
J P Nywening1, H Zhou, H Husain
1CH2M Hill Canada, 255 Consumers Road, Toronto, Ontario M2L 5B6, Canada. John-Paul.Nywening@ch2m.com
Abstract:
Parallel experimental tests to measure mixed liquor filterability for submerged membrane bioreactors were conducted over a six month period using three ZW-500 pilot plants and a ZW-10 lab-scale filterability apparatus. Non-air sparged conditions during the tests yielded operation behaviour that was equivalent to dead-end filtration. The fouling resistance increased linearly with the intercepted mass until a critical point was reached at which point significant cake compression was induced and the resistance began to increase exponentially. Although the point of cake compression appears to be dependent on the membrane module design, similar resistance per unit solid mass intercepted per unit area (R(mass)) values were observed when the same mixed liquor was filtered. Coupled with the established correlation between the R(mass) and the critical flux, it is suggested that the filterability test results from a side-stream, lab-scale module may be used to predict fouling potential in a full scale MBR wastewater treatment system without interrupting the full-scale MBR operation.
Related Concept Videos
Filtration
Bioreactor Design and Operational System
Scale-Up Processes
Bioreactor Controls-II