Related Experiment Video
Updated: Jul 11, 2026

A Quantitative Fluorescence Microscopy-based Single Liposome Assay for Detecting the Compositional Inhomogeneity Between Individual Liposomes
Published on: December 13, 2019
Characteristics of a liposome immunoassay on a poly(methyl methacrylate) surface
Sang Youn Hwang1, Yoichi Kumada, Gi Hoon Seong
1Department of Chemical Engineering, Hanyang University, Ansan, South Korea.
Abstract:
Liposome immunoassay (LIA) is based on enzyme immunoassay (EIA) but the detection sensitivity could be significantly enhanced by using antibody-coupled immunoliposomes encapsulating HRP (horse radish peroxidase). Here, we applied LIA to non-porous poly(methyl methacrylate) (PMMA) and polystyrene (PS) surfaces to compare its detection sensitivity with that of EIA, using rabbit IgG (a ligand molecule) and anti-rabbit IgG antibody (a capture molecule) as the model system. LIA developed much stronger color signals than EIA, especially at a lower concentration range (< ca. 1 microg mL(-1)). PMMA showed higher affinity toward rabbit IgG than the PS surface, and the anti-rabbit IgG antibody adsorbed on PMMA was more stable than that on PS. Furthermore, the effects of spot volume and antibody concentration on the signal density were analyzed. The signal density increased as the antibody concentration increased, but it was not significantly affected by the spot volume (2.5-20 microL). In conclusion, LIA on PMMA as a solid support is a very useful, highly sensitive microarray detection system.