Related Experiment Video
Updated: Jul 11, 2026

Measurement of the Hand Transmitted Vibration of the Human Hand Arm System During Operation of a Hand Tractor
Published on: June 16, 2021
A longitudinal study of finger systolic blood pressure and exposure to hand-transmitted vibration
Massimo Bovenzi1, Flavia D'Agostin, Francesca Rui
1Department of Public Health Sciences, University of Trieste, Centro Tumori, Trieste, Italy. bovenzi@units.it
Objectives:
To investigate prospectively the relation between vibration-induced white finger (VWF), exposure to hand-transmitted vibration (HTV) and the cold response of digital arteries in users of vibrating tools.
Methods:
Two-hundred and sixteen HTV workers and 133 control men of the same companies underwent initially a medical examination and a standardised cold test with measurement of the change in finger systolic blood pressure (FSBP) after finger cooling from 30 to 10 degrees C. They were re-examined 1 year later. Tool vibration magnitudes were expressed as frequency-weighted and unweighted r.m.s. accelerations. From the vibration magnitudes and exposure durations, alternative measures of cumulative vibration dose were calculated for each HTV worker, according to the expression: Sigma(alpha)(m)(i)(t)(i), where a ( i ) is the acceleration magnitude on tool i, t ( i ) is the lifetime exposure duration for tool i, and m = 0, 1, 2 or 4.
Results:
Among the HTV workers, the initial prevalence and the 1-year incidence of VWF were 18.1 and 1.7%, respectively. At the first examination, the HTV workers with moderate or severe score for VWF showed a significantly increased cold reaction in the fingers when compared with the controls and the HTV workers with no vascular symptoms. At the follow-up, the controls, the asymptomatic HTV workers, and the prevalent cases of VWF did not show significant changes in the cold response of digital arteries. A deterioration of cold-induced digital vasoconstriction was found in the incident cases of VWF. In the HTV workers, vibration doses with high powers of acceleration (i.e., Sigma(alpha)(m)(i)(t)(i) with m > 1) were major predictors of the vasoconstrictor response to cold at the follow-up examination.
Conclusions:
The measurement of FSBP after local cooling may be a helpful objective test to monitor prospectively the change in vibration-induced vascular symptoms. The findings of this longitudinal study suggest a dose-effect relationship between cold-induced digital arterial hyperresponsiveness over time and measures of cumulative vibration exposure. In the controls, the cold response of the digital arteries was stable over 1-year follow-up period.
Related Concept Videos
Assessment of blood pressure in brachial artery(two-step method)
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Measurement of Blood Pressure
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Pre-Procedural Guidelines for Assessing Blood Pressure

