Computer-assisted detection of pulmonary embolism: performance evaluation in consensus with experienced and
Christoph Engelke1, Stephan Schmidt, Annemarie Bakai
1Department of Radiology, University of Wuerzburg, 97080 Wuerzburg, Germany. engelke_c@klinik.uni-wuerzburg.de
Abstract:
The value of a computer-aided detection tool (CAD) as second reader in combination with experienced and inexperienced radiologists for the diagnosis of acute pulmonary embolism (PE) was assessed prospectively. Computed tomographic angiography (CTA) scans (64 x 0.6 mm collimation; 61.4 mm/rot table feed) of 56 patients (31 women, 34-89 years, mean = 66 years) with suspected PE were analysed by two experienced (R1, R2) and two inexperienced (R3, R4) radiologists for the presence and distribution of emboli using a five-point confidence rating, and by CAD. Informed consent was obtained from all patients. Results were compared with an independent reference standard. Inter-observer agreement was calculated by kappa, confidence assessed by ROC analysis. A total of 1,116 emboli [within mediastinal (n = 72), lobar (n = 133), segmental (n = 465) and subsegmental arteries (n = 455)] were included. CAD detected 343 emboli (sensitivity = 30.74%, correct-positive rate = 6.13/patient; false-positive rate = 4.1/patient). Inter-observer agreement was good (R1, R2: kappa = 0.84, 95% CI = 0.81-0.87; R3, R4: kappa = 0.79, 95% CI = 0.76-0.81). Extended inter-observer agreement was higher in mediastinal and lobar than in segmental and subsegmental arteries (kappa = 0.84-0.86 and kappa = 0.51-0.58 for mediastinal/lobar and segmental/subsegmental arteries, respectively P < 0.05). Agreement between experienced and inexperienced readers was improved by CAD (kappa = 0.60-0.62 and kappa = 0.69-0.72 before and after CAD consensus, respectively P < 0.05). The experienced outperformed the inexperienced readers (Az = 0.95, 0.93, 0.89 and 0.86 for R1-4, respectively, P < 0.05). CAD significantly improved overall performances of readers 3 and 4 (Az = 0.86 for R3, R4 and Az = 0.89 for R3, R4 with CAD, P < 0.05), by enhancing sensitivities in segmental/subsegmental arteries. CAD improved experienced readers' sensitivities in segmental/subsegmental arteries (sens. = 0.93 and 0.90 for R1, R2 before and 0.97 and 0.94 for R1, R2 after CAD consensus, P < 0.05), without significant improvement of their overall performances (P > 0.05). Particularly inexperienced readers benefit from consensus with CAD data, greatly improving detection of segmental and subsegmental emboli. This system is advocated as a second reader.
Related Concept Videos
Pulmonary Embolism II: Diagnostic Studies and Interprofessional Care
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Pulmonary Embolism I: Introduction
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Radiological Investigation I: X-ray and CT
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...