Related Experiment Video
Updated: Jul 11, 2026

A Mass Spectrometry-Based Approach to Identify Phosphoprotein Phosphatases and their Interactors
Published on: April 29, 2022
Mass spectrometric techniques for label-free high-throughput screening in drug discovery
Thomas P Roddy1, Christopher R Horvath, Steven J Stout
1Discovery Technologies, Novartis Institute for Biomedical Research, 250 Massachusetts Avenue, Cambridge, Massachusetts 02139, USA. thomas.roddy@novartis.com
Abstract:
High-throughput screening (HTS) is an important tool for finding active compounds to initiate medicinal chemistry programs in pharmaceutical discovery research. Traditional HTS methods rely on fluorescent or radiolabeled reagents and/or coupling assays to permit quantitation of enzymatic target inhibition or activation. Mass spectrometry-based high-throughput screening (MS-HTS) is an alternative that is not susceptible to the limitations imposed by labeling and coupling enzymes. MS-HTS offers a selective and sensitive analytical method for unlabeled substrates and products. Furthermore, method development times are reduced without the need to incorporate labels or coupling assays. MS-HTS also permits screening of targets that are difficult or impossible to screen by other techniques. For example, enzymes that are challenging to purify can lead to the nonspecific detection of structurally similar components of the impure enzyme or matrix of membraneous enzymes. The high selectivity of tandem mass spectrometry (MS/MS) enables these screens to proceed with low levels of background noise to sensitively discover interesting hits even with relatively weak activity. In this article, we describe three techniques that we have adapted for large-scale (approximately 175,000 sample) compound library screening, including four-way parallel multiplexed electrospray liquid chromatography tandem mass spectrometry (MUX-LC/MS/MS), four-way parallel staggered gradient liquid chromatography tandem mass spectrometry (LC/MS/MS), and eight-way staggered flow injection MS/MS following 384-well plate solid-phase extraction (SPE). These methods are capable of analyzing a 384-well plate in 37 min, with typical analysis times of less than 2 h. The quality of the MS-HTS approach is demonstrated herein with screening data from two large-scale screens.
Related Concept Videos
MALDI-TOF Mass Spectrometry
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...

